Furuno ARP-17 manual Specifications of Auto Plotter

Page 19

SPECIFICATIONS OF AUTO PLOTTER

ARP-17

1. GENERAL

(1)

Functions

• Calculation/indication of own ship speed relative to a fixed target

 

 

• Manual target acquisition, automatic tracking

 

 

• Target information:

 

 

Distance and bearing from own ship to target

 

 

Moving direction and speed

 

 

• History presentation

(2)

Acquisition and Tracking

 

 

 

• Manual acquisition by trackball and cursor

 

 

• Maximum number of targets: 10

 

 

• Acquisition range: 0.2 to 32 nm

 

 

• Tracking range: 0.1 to 32 nm

(3)

Vector

• Vector length: 30 sec; 1, 2, 3, 6, 15, 30 min

 

 

• Mode: true velocity or relative velocity

(4)

History

• plotting interval: 30 sec; 1,2,3,6 min

 

 

• Number of plotting points: 10 per target

(5)

Alarms

• Visual and audible alarm against target violating CPA/TCPA limits

 

 

• Visual and audible alarm against guard-zone limits (5 targets max.)

 

 

• Visual alarm against lost target, target full and system failure

(6)

Compatible Radar

FR-1700 series, FR-1500 Mark-3 series

SP - 1

Image 19
Contents Automatic Tracking AID B . N o . O M E 3 0 4 6 Safety Instructions Table of Contents Foreword FeaturesWord to Furuno ARP-17 Owners Acquisition and tracking Operational OverviewIntroduction Criteria of TrackingOther ship maneuvers Qualitative description of tracking errorAutomatic acquisition areas and suppression lines Own ship maneuversControls Controls, Menu DescriptionMenu description Menu treeEntering Own Ship’s Speed Activating, Deactivating the ATAAutomatic speed input Manual acquisition Acquiring TargetsManual speed input Target-based speed inputAutomatic acquisition Changing plot symbol shapeVectors Terminating Tracking of TargetsDisplaying Target Data Selecting plotting interval Past Position DisplaySet and Drift Displaying dataCPA/TCPA alarm AlarmsTrack Test Simulation Display Silencing CPA/TCPA audible alarmLost target alarm Guard zone alarmCPA Tcpa Diagnostic SequenceOutputting Target Data Specifications of Auto Plotter Index