Target | Course | Speed | CPA* | TCPA* |
|
|
|
|
|
Target 1 | 90.0° R | 10.0 kt | 1.0 nm | 10.4 min |
|
|
|
|
|
Target 2 | 0.0° R | 0.0 kt | 4.0 nm | — |
|
|
|
|
|
Target 3 | 180.0° R | 10.0 kt | 1.7 nm | 28.2 min |
|
|
|
|
|
Target 4 | 216.5° R | 23.8 kt | 0.9 nm | 15.0 min |
|
|
|
|
|
Target 5 | 273.5° R | 14.2 kt | 6.0 nm | 22.5 min |
|
|
|
|
|
Target 6 | 180.0° R | 20.0 kt | 0.0 nm | 30.0 min |
|
|
|
|
|
Target 7 | 24.6° R | 15.6 lkt | 4.0 nm | 43.6 min |
|
|
|
|
|
* Initial data
4.The simulation continues for five minutes and then repeats. To quit the test se- quence, turn the TRACK TEST off on the PLOT MENU2.
14. Diagnostic Sequence
You can check the ATA Board for proper op- eration as follows. The self test does not re- quire operator intervention. It runs automatically when the power is placed on at regular intervals or on operator demand.
1.Press [MENU], [0], [0], [0], [0].
2.Press the [2] key twice to start the diag- nosis sequence. The results of the test appear as shown below.
| |||
1. | Program No. | 03591521** | |
2. ROM Check | OK |
| |
3. RAM Check | OK |
| |
4. Antenna Rotation | 24RPM |
| |
5. | Tx Trigger Frequency 3000Hz |
| |
6. | Video Level | 000 |
|
7. | Video Signal | OK |
|
8. | Navigation I/O 1 | OK |
|
9. | Navigation I/O 2 | OK |
|
10. NMEA Heading IN OK |
| ||
11. LOG Pulse IN | OK |
| |
ARP TEST |
|
| |
1. | Program No. 18590411** 18590421** | ||
2. ROM Check | OK | OK | |
3. RAM Check | OK |
| |
4. Speed Log | OK 0.0 KT | ||
5. | Course | OK |
|
6. | Trigger | OK |
|
7. | Video Signal | OK |
|
8. | Bearing Pulse | OK |
|
9. | Heading Pulse | OK |
|
10. Minimum | 0003 |
| |
11. Scan Time | 0274 |
| |
12. Manual Acq. | 00 |
| |
13. Auto Acq. | 00 |
| |
14. | 0000 |
| |
15. | 0000 |
|
Press MENU key to escape.
Press ENTER to check CRT.
** Program No.
Figure 13 Diagnostics test results
(FR-1500 MARK-3 series)
3.If NG appears for any
4.To escape, press the [MENU] key.