TOA Electronics EX-16 Connection of the Input/Output Terminal, AC/DC Power Supply Connection

Page 20

3.7AC/DC Power Supply Connection

A 5P terminal for AC and DC power supply is provided on the DSM-16. The power cable, YA-308 or YA-309, can be connected to the 5P terminal. Be sure to ground the exchange.

5P Terminal on DSM-16

Power Supply Cables

YA-308

YA-309

3.8 Connection of the Input/Output Terminal

A 6P terminal for the input/output signals of the EX-16 is provided on the

DSM-16.

6P Terminal (DSM-16)

BGM IN

50K UNBAL

PAGING OUT

600 UNBAL

0dB

REMOTE OUT

MAX 125 VA

18

Image 20
Contents TOA EX-16 Intercom System Features Specifications Further Details System Block Diagram Features ExchangeFurther Details SpecificationsExchange Specifications EX-16 Dimensions in mm Paging Receiving Switch Transmitting Circuit Control signal System Block Diagram Stations Accessories Station SpecificationsWall Mounting Panel YC-100 Talk-Back Unit TKU-11Power Source Precautions for Installation ExchangeStations Distance as Functions of Core Diameter Cable InstallationCore Diameter Versus Transmission Distance Spacing WiringGeneral Information Piping ExampleConnection between the station and the exchange Clipping Tool C YC-105 Page AC/DC Power Supply Connection Connection of the Input/Output TerminalAll-Call Paging Output Remote Control OutputBGM Input Wiring Diagram Connection of the Talk-Back Unit Speaker Volume Adjustment Connection of the Speaker StationConnection with the Exchange 10.4 On/Off Control of BGMHow to Connect the Jumper Wire Jumper for Speaker Station Selection Jumper for BGM On/OffInspect Before Turning Power On Function SelectionTesting Adjusting Method PrecedurePage Trouble Shooting Guide Relationship Between Ambient Noise and Conversation ModeFault in Exchange Fault in Specific Station Only SymptomFault in Cable Line and R-Line are shorted or mixed up KOBE, Japan