Aiphone 410 operation manual Correcting or changing an ID setting

Page 3

Correcting or changing an ID setting:

In order tocorrect a programming error, the entrance station(s) and the tenant station(s) must be cleared of their incorrect program data, then programmed again correctly. Follow these steps to clear:

1.Put the system into programming mode using the procedure described on page 1, step 3.

2.At the tenant station, press and hold the door release button and bell button simultaneously until a beep is emitted from the unit (should take about 3 seconds). The internal memory is now cleared.

3.If using the GH-SW, press and hold the call button that you wish to clear until you hear a continuous beep. If using the GH-NS, display the resident info on the screen that you wish to clear, then press and hold the bell button(call button) untilyou hear a continuous beep. That address in the entry panel is now cleared.

4.You can now re-program the tenant station(s) using the procedure on page 1.

Programming multiple entrance stations / Concierge stations via Link Data:

If your system has more than one entrance panel and/or you’re using the GH-NS module or GH-MK Concierge station, you can send all of the tenant ID’s you just programmed to the other units using the Link Data feature. This can be done manually via the keypad on the entry panel or via the supplied software.

Using the keypad

Using the supplied software:

and scroll module:

1.Import the data from the GH-NS that you’ve set the ID’s on into the software with the LinkData box checked.

2.Export the data you just imported to each of your other GH-NS modules with the LinkData box checked.

Note: The GH-MK can be used to manually transfer data to other GH-MK’s or GH-NS’s in the system.

- 3 -

Image 3
Contents GH Series GH Series Installation Manual Supplement Correcting or changing an ID setting = PS-2420UL Page = PS-2420UL Page Page Page Page Page Page Page = PS-2420UL Page Page Page Page Page Page Page Page Specifications Toll Free Technical Support