8-6 Transfer entrance call
1 During communication with door station, press CALL button to call the transferring station.
•CALL button (red) flashes and the communication with door station is put on hold.
•The "All Call" function is activated to link all the master/sub stations.
English
3 If TALK button is pressed at the transferred station, communication with door station is performed (the transferring station's screen goes off). Press TALK button to end communication.
Français
Nederlands
2 If TALK button is pressed at the transferred station, the unit enters
NOTES: 1. If TALK button is pressed at the transferring station before starting communication between the transferred station and door station, the unit enters the condition where the forwarding source communicates with door station. After ending the
2.Communication (video) with door station ends automatically approx. 1 minute after first starting the communication.
Press TALK button within 30 seconds to start it again.
8-7 Automatic recording
If a call is received from video door station, the unit starts recording automatically. The record LED (red) flashes during recording
• The recording starts approx. 2 seconds after CALL button of video door station is pressed. A maximum length of approx. 8 seconds (8 shots) can be recorded with 1 picture and 1 shot for each second.
• A maximum of 50 pictures can be recorded (combined total of automatic recording and manual recording pictures). If 50 pictures are exceeded, pictures are overwritten starting from the picture with the oldest recording date.
NOTES: 1. The automatic recording function cannot be cancelled.
2.The screen shown when monitoring the entrance is not recorded automatically. If you wish to record this screen, press REC button.
8-8 Manual recording
1 Display a video image with an operation such as entrance monitoring. | 2 Press REC button. The record LED (red) flashes and recording starts. |
NOTES: 1. Manual recording is not possible during automatic recording (approx. 9 seconds after receiving a call from door station).
2.After the end of automatic recording (approx. 9 seconds have passed after receiving a call from the door station), another picture different from the automatically recorded picture is recorded.
•A maximum length of approx. 8 seconds (8 shots) can be recorded with 1 picture and 1 shot for each second.
•A maximum of 50 pictures can be recorded (combined total of automatic recording and manual recording pictures). If 50 pictures are exceeded, pictures are overwritten starting from the picture with the oldest recording date.
- 12 -