3M D-2400 installation instructions Communications Controller, Power Supply

Page 7

3M Model D-2400

Component Placement

Component Placement

This section describes placement of the 3M™ Convenience Store Intercom System, Model D-2400, components:

Communications Controller

For proper system operation, locate the Communications Controller:

1.Near the conduit termination of the Call Station wiring.

2.Near the power source.

3.At least 10 feet away from electrical noise sources such as the following:

-large electrical motors (such as air conditioners, freezers, and coolers)

-any electrical components that arc (i.e., relays)

-ballasts (for light fixtures)

4.In a secure room away from traffic.

5.Approximately 5 feet above the floor.

6.Where it is accessible from the top, bottom, and both sides.

7.In a dry and heated (between 50° and 100° Fahrenheit) location.

See Figure 2.

Power Supply

Locate the power supply as follows:

1.Install the power supply mounting bracket in a preferred location, as shown in Figure 2.

2.Insert the power supply transformer into the mounting bracket, as shown in Figure 2.

Figure 2. Suggested Communications Controller Placement

3

Image 7
Contents Convenience Store Intercom System FCC Information Front Matter Table of Contents System Components This page intentionally left blank Communications Controller Power SupplyStation Selectors Call StationsWiring the System Wiring Call Stations Communications Controller Jumpers Hardware JumpersParameter Value Programming the Selector Programming StateKey Function Keypad Function Definitions Programming StateLeft Arrow Parameter Selection Error MessageRe-Initializing the Selector Outbound Talk Volume Level Outbound ALL Call Volume LevelInbound Audio Volume Level Testing the Functions This page intentionally left blank Training Users Training Users Configuration Worksheets Configuration Worksheet MUSIC/MESSAGE Source Record Wire Colors Printed on recycled paper