Philips SE4502B manual Power requirements

Page 13

NOTES: This equipment may not be used on coin service provided by the telephone company.

3.1Power requirements

This product requires an electrical supply of 100-240 volts AC. In case of power failure, the communication can be lost.

The Electrical network is classified as hazardous. The only way to power down the charger is to unplug the power supply from the electrical outlet. Ensure that the electrical outlet is always easily accessible.

The voltage on the network is classified as TNV-3 (Telecommunication Network Voltages), as defined in the standard

UL 60950.

Warning

To avoid damage or malfunction:

Do not allow the charging contacts or the battery to come into contact with metal objects.

Do not open it as you could be exposed to high voltages.

Do not allow the charger to come into contact with liquids.

Never use any other battery than the one delivered with the product or recommended by Philips: risk of explosion.

Always use the cables provided with the product.

Handsfree activation could suddenly increase the volume in the earpiece to

a very high level: make sure the handset is not too close to your ear.

This equipment is not designed to make emergency calls when the power fails. An alternative has to be made available to allow emergency calls.

Do not expose the phone to excessive heat caused by heating equipment or direct sunlight.

Do not drop your phone or allow objects to fall on your phone.

Do not use any cleaning agents containing alcohol, ammonia, benzene, or abrasives as these may harm the set.

Do not use the product in places where there are explosive hazards.

Do not let small metal objects come into contact with the product. This can deteriorate audio quality and damage the product.

Active mobile phones in the vicinity

may cause interference. About operating and storage temperatures:

Operate in a place where temperature is always between 0 and 35º C (32 to 95º F).

Store in a place where temperature is always between -20 and 70º C (-4 to 158º F).

Battery life may be shortened in low temperature conditions.

Important

11

Image 13
Contents SE450 US-EN Telephone Page Table of contents Advanced settings 10.1 Easy Call Personal settings11.3 Call Forward when Unanswered Network ServiceTechnical data Frequently asked Questions56 Busy Activation Codes 11.2.2Read and understand all instructions Important Safety InstructionsDamage to the product Important Safety InstructionsBattery requirements Environment and safetyTelephone connection Precautions Following a power cut, the call in progress is lostEnvironmental care Notification to the Local Telephone Company Equipment Approval InformationRights of the Phone Company Environment and safety FCC RF Radiation Exposure Statement Hearing Aid CompatibilityPower requirements Electric, Magnetic and Electromagnetic Fields EMF Rbrc sealService Centers US service center Congratulations on your purchase and welcome to Philips Your phoneEarpiece Display Overview of your phone Event LEDSelect key o Back/Clear key cNumber keys Headset jack Battery doorMute key s Call transfer key & Intercom keyBack Display icons and MessagesClear Overview of the base station Paging key a Page handset Long press to start registration procedureGetting started Getting startedInstall battery Install your phoneSlide out the battery cover Icon Charge batteryTip Using multipacks Install optional headsetDiameter 2.5 mm SE450 has five menus as shown in the following table Menu structureMenu Name PhonebookList of languages Enter date & time Clock and AlarmEnter PIN Advanced SettingsNetwork Services Using your phone Enter a Dialing Pause Call using Direct Access MemoryAnswer a call Handsfree answeringUse more of your phone Chain dialing Access phonebookStore a contact in the phonebook SelectScroll n to Edit Entry and press o Select Modify a phonebook entry 1 Press m in idle modeView Delete all phonebook entries 1 Press m in idle mode Delete a phonebook entry 1 Press m in idle modeDirect Access Memory 7.1 Add/Edit Direct Access MemoryUsing the Redial list Delete Direct Access MemoryAccess Redial list Menu Scroll n to Delete and press o SelectAccess the Call log Using the Call logDelete a redial number Call waitingTo choose the format for call log display Display shows the caller informationSave call list entry into the phonebook Press o OKDelete a call list entry Using the IntercomPress o Menu Intercom another handset NoteBetween an internal or external call Answer an external call during intercomEstablish a three-party conference call Handset locatorSelect Scroll n to Alarm and press o Select Clock & Alarm, and press o SelectSet Date and Time Select Set Date/Time is highlighted. Press o SelectSet Alarm Tone Personal settingsSelect Handset Name is highlighted press o Select Ring Tones and press o Select Set the Ring TonesSelect Scroll n to Language and press o Select Scroll n to Color Theme and press o Select Default setting for auto hang up is OnScroll n to Backlight Time and press o Select Advanced Set and press o Select Advanced settingsSet Easy Call number Auto Conference Set Call Barring ModeScroll n to Change PIN and press o Select XHD SoundPrompted to enter the current PIN again Confirm PIN will be displayedSelect Scroll n to Register and press o Select Reset UnitEasy registration UnregisterSet Area Code Scroll n to Reset and press oScroll n to Auto Prefix and press Press o OK to confirm Prefix is displayed on the screenChange Flash time Change the Dial ModeAdvanced Set, and press o Select Default Settings Parameter Default Value Network ServiceParameter Default Value Call Forward Call Forward, Call ForwardChange Call Forward Activation Codes Select Scroll n to Call Forward and press o SelectNetw. Services, and press o Select Call Forward when BusyCall Forward screen Busy, scroll to Deactivate and press o SelectChange Call Forward when Unanswered Activation Codes Call Forward when UnansweredCall Fwd Busy screen Select Scroll n to Call Fwd Unans and press o SelectAccess Voice Mail Change Call Forward when Unanswered Deactivation CodeVoice Mail Set Voice Mail NumberSelect Scroll n to Settings and press o Select Access Info ServiceAccess the Call Return Service Set Call Return Service NumberSelect Scroll n to Cancel Call BK and press o Select Call the Cancel Call Back NumberSet the Cancel Call Back Number Withhold IDConnection Handset does not switch on Technical dataHandset does not charge Communication is lost during a call Icon is not blinking during chargePhone is Out of range Set-up Searching... is displayed on handsetMy handset keeps going into idle mode Cannot change the settings of my voice mailHandset cannot be registered to the base station Caller number is not displayedIndex Index Set Info Service Number Set the Backlight Time UCZZ01978UZ0

SE4502B specifications

The Philips SE4502B is a standout model in the landscape of advanced healthcare technology, specifically designed for patient monitoring and diagnostic purposes. This device is equipped with a range of features that enhance its usability and functionality, making it an invaluable tool for healthcare professionals.

One of the primary features of the SE4502B is its high-resolution display. The bright, clear screen allows for easy visibility of critical patient data, even in low-light environments. This is crucial in emergencies where quick and accurate readings can make significant differences in patient outcomes.

The SE4502B is powered by state-of-the-art monitoring technologies that ensure real-time data collection and analysis. The device captures vital signs such as heart rate, blood pressure, respiratory rate, and temperature, all of which are essential for comprehensive patient assessments. The integration of advanced algorithms allows for precise measurements, minimizing errors and improving the reliability of the data collected.

Another notable aspect of the SE4502B is its connectivity options. The device is designed to seamlessly integrate with existing hospital systems, allowing for efficient data sharing and management. This connectivity not only boosts the operational efficiency of healthcare facilities but also supports telemedicine applications, broadening access to care for patients in remote locations.

Durability and ease of use are also key characteristics of the Philips SE4502B. The device is built to withstand the rigors of a clinical environment, ensuring longevity and consistent performance even under stress. Its user-friendly interface simplifies operation, allowing healthcare providers to focus more on patient care rather than navigating complex systems.

Moreover, the SE4502B includes customizable alerts and notifications, which help healthcare teams respond swiftly to changes in a patient’s condition. The ability to tailor these alerts based on individual patient needs enhances the overall quality of care.

In summary, the Philips SE4502B is a sophisticated and reliable device that combines advanced monitoring technologies with practical features tailored for real-world medical settings. Its high-resolution display, real-time monitoring, seamless connectivity, and durability make it an essential tool for healthcare providers dedicated to delivering high-quality patient care. The SE4502B is a testament to Philips’ commitment to innovation in healthcare technology, significantly improving patient monitoring and outcomes in clinical settings.