Casio IT-2000 installation manual Setup of Master I/O Box

Page 11
2.3.2Setup of Master I/O Box

2.3.2Setup of Master I/O Box

Note that the DIP switch settings of the Master I/O Box differ depending on whether the

system configuration is consisted of only single Master I/O Box or of multiple Master I/O Boxes that are￿followed by Satellite I/O Boxes.

Make sure that the POWER switch of the I/O Box is set to OFF. Set the DIP switch at the rear of the unit as follows:

 

1

2

3

4

5

6

7

8

9

10

￿

ON

OFF

OFF

OFF

ON

OFF

OFF

OFF

ON

ON

Setup for the SCSI ID (DIP switches nos. 6, 7, and 8)

This SCSI ID must be different from that of other I/O Boxes or the PC.

Since generally the SCSI ID of the PC is set to 7, set the SCSI ID of the I/O Box to a number between 0 and 6.

 

SCSI-ID

6

7

8

 

ID0

OFF

OFF

OFF

 

ID1

ON

OFF

OFF

 

ID2

OFF

ON

OFF

 

ID3

ON

ON

OFF

 

ID4

OFF

OFF

ON

 

ID5

ON

OFF

ON

 

ID6

OFF

ON

ON

￿

ID7

ON

ON

ON

Setup termination for SCSI interface (no. 9)

Set DIP switch no.9 of the I/O Box, which is the farthest from the PC, to ON.

This setting is the same if only one I/O Box is connected.

￿

SCSI termination setup

 

9

 

Termination

 

ON

 

Non-termination

 

OFF

 

Power setup for termination of SCSI interface (no.10)

If the SCSI board in the PC cannot supply power to the SCSI interface, set DIP switch no.10 of the I/O Box, which is the nearest to the PC, to ON. However, DIP switch no. 10 is usually set to OFF, since a general SCSI board can supply power to the SCSI interface.

11

Image 11
Contents Version AprilCopyright 1998. All rights reserved IT-2000 I/O Box Installation ManualAppendix Table of Contents1. Overview Software 2. System Configuration and Installation Method2.1 Options and Software 2.2.2 With Multiple I/O Boxes 2.2 System Configuration2.2.1 With Single I/O Box 2.2.4 With Multiple Master I/O Boxes 2.2.3 With Single Master I/O Box2.2.5 With Master and Satellite I/O Boxes 2.3 Installation Method With Multiple Satellite I/O Boxes 2.3.1 Setup of Satellite I/O BoxWith single Satellite I/O Box I/O Box This is for the termination 2.3.2 Setup of Master I/O Box 2.3.3 Setup of Satellite I/O Box to Master I/O Box Startup 2.3.4 Setup of PCConnection Environment Setup Operation on PC 3. Operation Method3.1 File Upload 3.1.1 Specifying Files from PCDoFLINK argc, argv argc = argv = fl Operation on IT-2000FLINK.DLL of Windows 3.1 version FLINK.EXE of MS-DOS version 3.1.2 Specifying Files from IT-2000FLINK.DLL of Windows 3.1 version 3.2.1 Specifying Files from PC 3.2 File DownloadFLINK.DLL of Windows 3.1 version FLINK /R CFILE D 3.2.2 Specifying Files from IT-2000DoFLINK argc, argv argc = argv = fl , /r, CFILE, Dyyy 4. Error Codes and Error Messages Detai CategTable 4.2 Error codes and error messages Satellite I/O Box 5. Q and ACommon to Satellite and Master I/O Boxes Master I/O Box Can I update the version of Master I/O Box firmware ? IT-2000 Technical Reference Manual IT-2000 Hardware Manual 6. Reference ManualsIT-2000 Upload/Download Utility Manual SCSI Cable 7. List of SCSI Boards and SCSI CablesSCSI Board setup Appendix Installation Method of Upload/Download UtilityInstallation Syntax of the Installer Command