Casio IT-2000 installation manual Master I/O Box

Page 27
Master I/O Box

Q2

If the Windows3.1 version of FLINK is used, the baud rate setup cannot be modified by changing the DIP switch setting for the RS-232C communication speed on the Satellite I/O Box. Why?

A2

To modify the RS-232C communication speed with the Windows3.1 version of FLINK, it must be started up with the following option. Otherwise, the default value of 9600 bps is automatically used.

Option: /L {baud rate parameter,2,,,,,,, }

9600 for 9600 bps

384K for 38400 bps

115K for 115200 bps

The communication speed can be determined according to the DIP switch setting of the Satellite I/O Box only if the MS-DOS version of FLINK is used.

Q3

If an attempt is made to execute the Upload/Download Utility, a startup error appeared. Why?

A3

This startup error occurs if the COM port is being used by another application.

In addition, if an application that uses the COM port is executed from the DOS window, the COM port is not accessible from other applications until the DOS window has been closed.

Q4

If multiple Satellite I/O Boxes are connected under daisy-chain, can each IT-2000 terminal independently use either the MS-DOS version of FLINK or the Windows3.1 version of FLINK ?

A4

This is not permitted. All IT-2000 terminals must use the same version.

Master I/O Box

Q1

If the Master I/O Box is connected, the SCSI check box in LMWIN cannot be selected. Why?

A1

First turn ON the power to the Master I/O Box, then turn ON the power to the PC. If this order is reversed, the I/O Box cannot be recognized by the system. Or, SCSI IDs may be duplicated. Check this.

27

Image 27
Contents Version AprilCopyright 1998. All rights reserved IT-2000 I/O Box Installation ManualAppendix Table of Contents1. Overview 2. System Configuration and Installation Method 2.1 Options and SoftwareSoftware 2.2 System Configuration 2.2.1 With Single I/O Box2.2.2 With Multiple I/O Boxes 2.2.4 With Multiple Master I/O Boxes 2.2.3 With Single Master I/O Box2.2.5 With Master and Satellite I/O Boxes 2.3 Installation Method 2.3.1 Setup of Satellite I/O Box With single Satellite I/O BoxWith Multiple Satellite I/O Boxes I/O Box This is for the termination 2.3.2 Setup of Master I/O Box 2.3.3 Setup of Satellite I/O Box to Master I/O Box 2.3.4 Setup of PC ConnectionStartup Environment Setup Operation on PC 3. Operation Method3.1 File Upload 3.1.1 Specifying Files from PCOperation on IT-2000 FLINK.DLL of Windows 3.1 versionDoFLINK argc, argv argc = argv = fl FLINK.EXE of MS-DOS version 3.1.2 Specifying Files from IT-2000FLINK.DLL of Windows 3.1 version 3.2.1 Specifying Files from PC 3.2 File DownloadOperation on IT-2000 FLINK /R CFILE D 3.2.2 Specifying Files from IT-2000DoFLINK argc, argv argc = argv = fl , /r, CFILE, Dyyy 4. Error Codes and Error Messages Detai CategTable 4.2 Error codes and error messages 5. Q and A Common to Satellite and Master I/O BoxesSatellite I/O Box Master I/O Box Can I update the version of Master I/O Box firmware ? 6. Reference Manuals IT-2000 Upload/Download Utility ManualIT-2000 Technical Reference Manual IT-2000 Hardware Manual 7. List of SCSI Boards and SCSI Cables SCSI BoardSCSI Cable setup Appendix Installation Method of Upload/Download UtilityInstallation Syntax of the Installer Command