Mitsubishi Electronics FR-S500 instruction manual Error Code List, Operation at alarm occurrence

Models: FR-S500

1 196
Download 196 pages 9.03 Kb
Page 155
Image 155
<Error Code List>

Communication parameters

<Error Code List>

The corresponding error code in the following list is displayed if an error is detected in any communication request data from the computer:

Error

Item

Definition

Inverter

Code

Operation

 

 

 

Computer

The number of errors consecutively detected in

 

H0

communication request data from the computer is

 

NAK error

 

 

greater than allowed number of retries.

 

 

 

Brought to an

H1

Parity error

The parity check result does not match the specified parity

H2

Sum check

The sum check code in the computer does not match

alarm stop (OPT)

error

that of the data received by the inverter.

if error occurs

 

 

 

 

continuously

 

Protocol

Data received by the inverter is in wrong protocol, data

H3

receive is not completed within given time, or CR and

more than the

error

 

LF are not as set in the parameter.

allowable number

 

 

 

 

 

of retries.

H4

Framing

The stop bit length is not as specified by initialization.

error

 

 

 

 

H5

Overrun

New data has been sent by the computer before the

 

error

inverter completes receiving the preceding data.

 

 

 

H6







 

Character

The character received is invalid (other than 0 to 9, A to

Does not accept

H7

received data but

error

F, control code).

is not brought to

 

 

 

 

alarm stop

H8







H9







HA

Mode error

Parameter write was attempted in other than the computer

Does not accept

 

 

link operation mode or during inverter operation.

HB

Instruction

The specified command does not exist.

received data but

code error

is not brought to

 

 

 

 

 

alarm stop.

HC

Data range

Invalid data has been specified for parameter write,

error

frequency setting, etc.

 

 

 

HD







HE







HF







(5) Operation at alarm occurrence

 

 

 

Operation Mode

Fault Location

Status

Communication

 

Operation

External Operation

 

 

 

 

 

 

(RS-485 connector)

 

Inverter fault

Inverter operation

Stop

Stop

Communication

RS-485

Continued

Continued

 

connector

Communication error

Inverter operation

 

Stop/continued (*3)

Continued

(Communication from

Communication

RS-485

Stop

Stop

RS-485 connector)

connector

*3: Can be selected using the corresponding parameter (factory-set to stop).

(6) Communication error

Fault Location

Error Message

Remarks

(Operation panel)

 

 

Communication error

OPT

Error code is OPT

(Communication from RS-485 connector)

 

 

2

FUNCTIONS

145

Page 155
Image 155
Mitsubishi Electronics FR-S500 instruction manual Error Code List, Operation at alarm occurrence, Communication error