Mitsubishi Electronics FR-S500 How to make a restart after a stop by the RESETSTOP input from the

Models: FR-S500

1 196
Download 196 pages 9.03 Kb
Page 116
Image 116
(1)How to make a restart after a stop by the RESETSTOP input from the

Operation selection function parameters

(1)How to make a restart after a stop by the RESETSTOP input from the

operation panel (Restarting method with operation panel (Restarting method with  shown) shown)

1.After completion of deceleration to a stop, switch off the STF or STR signal.

2. Press the EXTPU to show PU

( input canceled)

3.Press the EXTPU to return to EXT .

4.Switch on the STF or STR signal.

 

Speed

 

Time

 

 

PU

Operation

 

EXT

 

panel

ON

STOP

 

STF

RESET

 

(STR) OFF

 

 

Stop and restart example for external operation

REMARKS

•If the reset signal (RES) is provided during operation, the inverter shuts off its output while it is reset, the internal thermal integrated value of the electronic thermal relay function and the

number of retries are reset, and the motor coasts.

•The Pr. 75 value can be set any time. Also, if parameter (all) clear is executed, this setting will not return to the initial value.

•When the inverter is stopped by the PU stop function, the display alternates between

Manual backgroundManual backgroundManual backgroundManual background. An alarm is not output.

(2)How to make a restart when a stop is made by the RESETSTOP from the PU

Manual backgroundManual backgroundManual backgroundManual background and

input

1.After completion of deceleration to a stop, switch off the STF or STR signal.

2.Press the EXT .

(Manual background canceled)

3.Switch on the STF or STR signal.

 

Speed

Time

Operation

EXT

panel

 

STOP

STF

ON

RESET

(STR) OFF

 

Stop and restart example for external operation

Besides the above operations, a restart can be made by performing a power-on reset or resetting the inverter with the inverter's reset terminal.

REMARKS

•If the reset signal (RES) is provided during operation, the inverter shuts off its output while it is reset, the internal thermal integrated value of the electronic thermal relay function and the

number of retries are reset, and the motor coasts.

•To resume operation, reset the inverter after confirming that the PU is connected securely.

•The Pr. 75 value can be set any time. Also, if parameter (all) clear is executed, this setting will not return to the initial value.

•When the inverter is stopped by the PU stop function, PS is displayed but an alarm is not output.

106

Page 116
Image 116
Mitsubishi Electronics FR-S500 instruction manual How to make a restart after a stop by the RESETSTOP input from the