Errors (Alarms)

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation Panel Indication

THM

 

 

 

 

FR-PU04

Motor Overload

 

 

 

 

 

Name

Motor overload

shut-off (electronic thermal

relay function) (* 1)

 

The electronic thermal relay function in the inverter detects motor

 

overheat due to overload or reduced cooling capability during low-

Description

speed operation to stop the inverter output. When a multi-pole

motor or two or more motors are run, provide a thermal relay on

 

 

the output side of the inverter.

 

 

 

Protection from burning due to motor temperature rise.

Check point

Check the motor for use under overload.

 

Corrective action

• Reduce the load weight.

 

 

• For a constant-torque motor, set the constant-torque motor in Pr.

 

71 "applied motor".

 

 

 

 

 

 

Operation Panel Indication

THT

 

 

 

 

FR-PU04

Inv. Overload

 

 

 

 

 

Name

Inverter overload shut-off (electronic thermal relay function) (* 1)

 

If a current of more than 150% of the rated output current flows

 

and overcurrent shut-off does not occur (150% or less), inverse-

Description

time characteristics cause the electronic thermal relay function to

be activated to stop the inverter output in order to protect the

 

 

output transistors.

 

 

 

Output transistor protection from overheat

 

Check point

Check the motor for use under overload.

 

Corrective action

Reduce the load weight.

 

 

*1. Resetting the inverter initializes the internal thermal integratied data of the electronic thermal relay function.

Operation Panel Indication

FIN

 

 

FR-PU04

H/Sink O/Temp

 

 

 

 

 

 

Name

Fin overheat

 

 

 

 

Description

If the heatsink overheats, the temperature sensor is actuated to

stop the inverter output.

 

 

 

 

 

Check point

• Check for too high ambient temperature.

 

• Check for heatsink clogging.

 

 

 

 

 

Corrective action

Set the ambient temperature to within the specifications.

Operation Panel Indication

BE

 

FR-PU04

 

Br. Cct. Fault

 

 

 

 

 

 

Name

Internal circuit

error

 

 

 

Description

Appears when an internal circuit error occurred.

 

Corrective action

Please contact your sales representative.

 

PROTECTIVE FUNCTIONS

3

159

Page 169
Image 169
Mitsubishi Electronics FR-S500 instruction manual Motor Overload, Inv. Overload, Sink O/Temp, Br. Cct. Fault