2.13 Calibration parameters

Calibration parameters

2.13 Calibration parameters

2.13.1 Meter (frequency meter) calibration (C1 2.13.1 Meter (frequency meter) calibration (C1 ))

The AM terminal is factory-set to provide 5VDC output in the full-scale status of each monitor item. However, calibration parameter C1 can be used to adjust the output voltage ratio (gain) according to the meter scale. Note that the maximum output voltage is 5VDC.

Parameter

Name

Factory Setting

Setting Range

Remarks

C1 (901)

AM terminal





Setting is enabled when

calibration

Pr. 30 = "1"

 

 

 

The parameter number in parentheses is the one for use with the parameter unit (FR- PU04).