Mitsubishi Electronics FR-S500 instruction manual speed, Multi

Models: FR-S500

1 196
Download 196 pages 9.03 Kb
Page 193
Image 193
speed-

 

 

 

 

 

 

 

Parameter Instruction Code List

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instruction

Computer

Link Parameter

Func-

Parameter

Name

 

 

Code

Link Data

Extension Setting

tion

Number

Read

Write

Setting

(Instruction

 

 

 

 

Increments *

Code 7F/FF)

 

80

Multi-speed setting

50

D0

0.01Hz

0

 

(speed 8)

 

 

 

 

 

 

 

 

 

81

Multi-speed setting

51

D1

0.01Hz

0

 

(speed 9)

operation

83

53

D3

0.01Hz

0

Multi-speed setting

 

82

Multi-speed setting

52

D2

0.01Hz

0

 

(speed 10)

 

 

 

 

 

 

 

 

speed-

 

(speed 11)

 

 

 

 

 

 

 

84

Multi-speed setting

54

D4

0.01Hz

0

 

(speed 12)

 

 

 

 

 

 

 

 

Multi

85

Multi-speed setting

55

D5

0.01Hz

0

(speed 13)

 

 

 

 

 

 

 

 

 

 

86

Multi-speed setting

56

D6

0.01Hz

0

 

(speed 14)

 

 

 

 

 

 

 

 

 

87

Multi-speed setting

57

D7

0.01Hz

0

 

(speed 15)

 

 

 

 

 

 

 

 

 

88

PID action selection

58

D8

1

0

control

89

PID proportional band

59

D9

0.1%

0

90

PID integral time

 

 

5A

DA

0.1s

0

91

PID upper limit

 

 

5B

DB

0.1%

0

 

 

 

PID

92

PID lower limit

 

 

5C

DC

0.1%

0

93

PID action set point for

 

 

5D

DD

0.01%

0

 

 

 

 

PU operation

 

 

 

 

 

 

 

 

 

 

 

94

PID differential time

 

 

5E

DE

0.01s

0

 

95

Rated motor slip

 

 

5F

DF

0.01%

0

 

96

Slip compensation time

60

E0

0.01s

0

functions

constant

 

 

 

 

 

 

 

 

selection

 

 

 

 

 

 

 

97

Constant-output region

61

E1

1

0

 

slip compensation

 

 

 

 

 

 

 

 

 

Sub

98

Automatic torque boost

62

E2

0.01kW

0

selection

 

 

 

(Motor capacity)

 

 

 

 

 

 

 

99

Motor primary resistance

63

E3

0.001Ω

0

 

H1 (503)

Maintenance timer

03

1

5

 

 

 

 

 

 

 

 

H2 (504)

Maintenance timer alarm

04

84

1

5

Maintenance function

 

output set time

 

 

 

 

 

 

H3 (555)

Current average time

37

B7

0.1s

5

 

 

 

 

 

 

 

 

 

H4 (556)

Data output mask time

38

B8

0.1s

5

 

 

 

 

 

 

 

 

 

 

H5 (557)

Current average value

39

B9

0.01A

5

 

monitor signal output

 

 

reference current

 

 

 

 

 

 

183

Page 193
Image 193
Mitsubishi Electronics FR-S500 instruction manual speed, Multi