Mitsubishi Electronics FR-S500 instruction manual Data used is hexadecimal, Data format types

Models: FR-S500

1 196
Download 196 pages 9.03 Kb
Page 145
Image 145
(3) Data format

Communication parameters

REMARKS

*1. Setting any of "0.1" to "999" in Pr. 37 "speed display" and "1" in instruction code "HFF" sets the data format to A" or E" (6-digit data). Also, the output frequency turns to a speed display, which is valid in 0.01r/min increments. (The third decimal place is invalid.) If the instruction code "HFF" is other than "1", the display is in 1r/min increments and a 4-digit data format can be used. Reply data is given in format E if the requested monitor data has 4 digits, in format E' if the data has 2 digits, or in format E" if the data has 6 digits.

*2. The data format to read/write Pr. 37 "speed display" is always E"/A" (6-digit data).

(3) Data format

Data used is hexadecimal.

Data is automatically transferred in ASCII between the computer and inverter.

Data used is hexadecimal. Data format types

1) Communication request data from computer to inverter

[Data write]

Format A

Format A'

Format A"

[Data read]

Format B

 

*1

 

*2

Instruction

*3

 

 

 

 

 

Sum

 

 

 

 

 

 

 

 

 

Inverter

Waiting

 

Data

 

 

*4

 

 

 

 

 

 

 

 

ENQ

numberstation

 

code

 

 

 

check

 

 

 

 

 

 

 

 

 

time

 

 

 

 

 

 

 

 

Number of

1

2

3

4

5

6

7

8

9

10

11

12

13

 

 

 

 

characters

 

 

 

*1

 

*2

Instruction

*3

Data

Sum

*4

 

 

 

 

 

 

 

 

 

 

 

Inverter

Waiting

 

 

 

 

 

 

 

 

 

 

 

ENQ

numberstation

 

code

time

 

 

check

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

 

Number of characters

 

 

*1

 

*2

Instruction

*3

 

 

 

 

 

 

 

 

Sum

 

 

 

 

 

Inverter

Waiting

 

 

Data

 

 

 

*4

 

 

 

 

ENQ

numberstation

 

code

time

 

 

 

 

 

check

 

 

Number

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

 

 

of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

characters

 

*1

 

*2

Instruction

*3

Sum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inverter

Waiting

*4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENQ

numberstation

 

code

time

check

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

 

Number of characters

 

 

 

 

 

 

 

2) Reply data from inverter to computer during data write

 

 

[No data error detected]

 

 

 

 

 

 

 

 

 

[Data error detected]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1

 

*2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1

 

*2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Format C

 

Inverter

*4

 

 

 

 

 

 

 

 

Format D

 

Inverter

 

Error

*4

 

 

 

 

 

 

 

 

 

 

 

 

numberstation

 

 

 

 

 

 

 

 

 

 

numberstation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NAK

 

code

 

 

 

 

Number

 

 

 

 

 

 

 

 

 

 

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2 3 4

 

 

 

 

 

 

 

 

 

 

 

 

1 2 3 4 5

 

 

 

 

 

 

 

 

 

 

 

 

 

of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

characters

3) Reply data from inverter to computer during data read

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[No data error detected]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Data error detected]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1

 

*2

 

 

 

Read

 

 

*1

Sum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Format E

 

Inverter

 

 

 

 

 

*4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STX

station

 

 

 

data

 

 

ETX

check

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

number

 

 

 

 

 

 

 

 

 

 

Format F

 

 

 

 

 

 

 

 

 

1

2

3

4

 

 

5

6

7

 

8

9

10

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1

 

*2

Read

 

*1

Sum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1

*2

 

 

Error

 

 

 

 

Format E'

 

Inverter

 

*4

 

 

 

 

 

 

Number

 

 

Inverter

 

*4

 

 

 

 

STX

station

data

 

ETX

check

 

 

 

 

 

 

 

 

 

NAK

station

 

code

 

 

 

 

 

 

number

 

 

 

 

 

 

 

 

 

of

 

 

 

number

 

 

 

 

 

 

 

1

2

3

4

 

 

5

6

7

 

8

9

 

 

 

 

 

 

characters

1

2 3

4 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1

 

*2

 

 

 

 

 

 

Read

 

 

*1

 

 

Sum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Format E''

 

Inverter

 

 

 

 

 

 

 

 

 

 

 

*4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STX

station

 

 

 

 

 

 

data

 

 

ETX

check

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of

 

 

 

 

 

 

1

2

3

4

 

 

5

6

7

 

8

9

10

11

12

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

FUNCTIONS

135

Page 145
Image 145
Mitsubishi Electronics FR-S500 instruction manual Data used is hexadecimal, Data format types, Communication parameters