<Setting items and set data>

Communication parameters

<Setting items and set data>

After completion of parameter settings, set the instruction codes and data then start communication from the computer to allow various types of operation control and monitoring.

 

 

 

 

Instruction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number

No.

 

Item

 

 

 

 

 

 

 

Description

 

 

 

 

 

 

 

of Data

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digits

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H0000: Communication operation

 

 

 

 

 

 

 

 

1

Operation

Read

H7B

H0001: External operation

 

 

 

 

 

 

 

 

 

 

4 digits

mode

 

 

H0002: PU operation

 

 

 

 

 

 

 

 

 

 

 

 

 

Write

HFB

H0000: Communication operation

 

 

 

 

 

 

 

 

 

 

 

H0001: External operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H0000 to HFFFF: Output frequency in 0.01Hz

 

 

 

 

 

 

increments

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr. 37 = 0 (factory setting)

 

 

 

 

 

 

 

 

 

 

4 digits

 

 

Output

 

H0000 to HFFFF: Speed in 1r/min increments

 

 

 

 

 

 

frequency

H6F

When Pr. 37 = "0.1 to 999", expansion link parameter (HFF)

 

 

 

[speed]

 

= 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H000000 to HFFFFFF: Speed in 0.01r/min increments

 

 

 

 

 

 

When Pr. 37 = "0.1 to 999", expansion link parameter (HFF)

6 digits

 

 

 

 

 

= 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

H70

H0000 to HFFFF: Output current (hexadecimal) in 0.01A

4 digits

 

 

current

 

increments

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H0000 to HFFFF: Two most recent alarm definitions

 

 

 

 

 

 

Alarm definition display example (instruction code H74)

 

 

Monitoring

 

 

b15

 

 

 

 

 

b8b7

 

 

 

b0

 

 

 

0

0

1

1

0

0

0

0

1

0

1

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Previous alarm Most recent alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm data

 

(H30)

 

 

(HA0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm

 

 

Data

Description

Data

 

 

Description

 

 

 

 

H74 to H75

 

H00

No alarm

H60

 

 

OLT

 

4 digits

 

 

definition

 

H10

OC1

H70

 

 

BE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H11

OC2

H80

 

 

GF

 

 

 

 

 

 

 

 

H12

OC3

H90

 

 

OHT

 

 

 

 

 

 

 

 

H20

OV1

HA0

 

 

OPT

 

 

 

 

 

 

 

 

H21

OV2

HB0

 

 

PE

 

 

 

 

 

 

 

 

H22

OV3

HB1

 

 

PUE

 

 

 

 

 

 

 

 

H30

THT

HB2

 

 

RET

 

 

 

 

 

 

 

 

H31

THM

HC0

 

 

CPU*

 

 

 

 

 

 

 

 

H40

FIN

 

 

 

 

 

 

 

 

 

 

 

* Error code may not be returned.