Mitsubishi Electronics FR-S500 instruction manual Function Parameter list

Models: FR-S500

1 196
Download 196 pages 9.03 Kb
Page 58
Image 58
Function (Parameter) list

Parameter List

Function (Parameter) list

2.1 Function (Parameter) list

CAUTION

2.1 Function (Parameter) listManual background indicates that the setting can be changed during operation if Pr. 77 "parameter

write disable selection" has been set to "0" (factory setting). (Note that the Pr. 53, Pr. 70 and Pr. 72 values can be changed only during PU operation.)

Parameter

Indica-

Name

Setting

Minimum

Factory

Refer

Cus-

Setting

tomer

 

tion

 

Range

Increments

Setting

To:

Setting

0

 

Torque boost

0 to 15%

0.1%

6%/5%/

63

 

 

4%/

 

 

 

 

 

 

(*1)

 

 

1

 

Maximum frequency

0 to 120Hz

0.1Hz

60Hz

64

 

 

 

 

 

 

 

 

 

2

 

Minimum frequency

0 to 120Hz

0.1Hz

0Hz

64

 

 

 

 

 

 

 

 

 

3

 

Base frequency

0 to 120Hz

0.1Hz

60Hz

65

 

 

 

 

 

 

 

 

 

4

 

Multi-speed setting

0 to 120Hz

0.1Hz

60Hz

66

 

 

(high speed)

 

 

 

 

 

 

 

 

5

 

Multi-speed setting

0 to 120Hz

0.1Hz

30Hz

66

 

 

(middle speed)

 

 

 

 

 

 

 

 

6

 

Multi-speed setting

0 to 120Hz

0.1Hz

10Hz

66

 

 

(low speed)

 

 

 

 

 

 

 

 

7

 

Acceleration time

0 to 999s

0.1s

5s

67

 

 

 

 

 

 

 

 

 

8

 

Deceleration time

0 to 999s

0.1s

5s

67

 

 

 

 

 

 

 

 

 

9

 

Electronic thermal O/L

0 to 50A

0.1A

Rated

69

 

 

output

 

 

 

relay

 

 

current

 

 

 

 

 

 

 

 

 

30

 

Extended function

0, 1

1

0

80

 

 

display selection

 

 

 

 

 

 

 

 

79

 

Operation mode

0 to 4, 7, 8

1

0

109

 

 

selection

 

 

 

 

 

 

 

 

*1. The factory setting varies with the inverter capacity: 5% for FR-S540E-1.5K and 2.2K, 4% for FR-S540E-3.7K.

48

Page 58
Image 58
Mitsubishi Electronics FR-S500 instruction manual Function Parameter list