Parameter List

Function (Parameter) list

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Func-

Para-

Indica-

Name

Setting Range

Minimum

Factory

Refer

Cus-

tion

meter

tion

Setting

Setting

To:

tomer

 

 

 

 

Increments

Setting

 

 

 

Multi-speed

 

 

 

 

 

 

 

 

24

 

setting

0 to 120Hz, - - -

0.1Hz

- - -

66

 

 

 

 

(speed 4)

 

 

 

 

 

 

 

 

 

 

Multi-speed

 

 

 

 

 

 

 

 

25

 

setting

0 to 120Hz, - - -

0.1Hz

- - -

66

 

 

 

 

(speed 5)

 

 

 

 

 

 

 

 

 

 

Multi-speed

 

 

 

 

 

 

 

 

26

 

setting

0 to 120Hz, - - -

0.1Hz

- - -

66

 

 

 

 

(speed 6)

 

 

 

 

 

 

 

 

 

 

Multi-speed

 

 

 

 

 

 

 

 

27

 

setting

0 to 120Hz, - - -

0.1Hz

- - -

66

 

 

 

 

(speed 7)

 

 

 

 

 

 

 

 

 

 

Stall

 

 

 

 

 

 

 

 

 

 

prevention

 

 

 

 

 

 

 

 

28

 

operation

0 to 120Hz

0.1Hz

60Hz

77

 

 

 

reduction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

starting

 

 

 

 

 

 

 

 

 

 

frequency

 

 

 

 

 

 

 

functions

 

 

pattern

0: Linear acceleration/

 

 

 

 

 

 

deceleration A,

 

 

 

 

 

 

 

Acceleration/

deceleration,

 

 

 

 

 

29

 

1: S-pattern acceleration/

1

0

79

 

 

 

deceleration

 

 

 

 

operation

 

 

Frequency

2: S-pattern acceleration/

 

 

 

 

 

 

deceleration B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter 30 is basic function parameter.

 

 

 

Standard

31

 

jump 1A

0 to 120Hz, - - -

0.1Hz

- - -

80

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

 

 

 

 

 

 

 

32

 

Frequency

0 to 120Hz, - - -

0.1Hz

- - -

80

 

 

 

jump 1B

 

 

 

 

 

 

 

 

 

 

 

 

33

 

jump 2A

0 to 120Hz, - - -

0.1Hz

- - -

80

 

 

 

 

 

 

 

 

 

 

 

 

34

 

Frequency

0 to 120Hz, - - -

0.1Hz

- - -

80

 

 

 

jump 2B

 

 

 

 

 

 

 

 

 

 

 

 

35

 

Frequency

0 to 120Hz, - - -

0.1Hz

- - -

80

 

 

 

jump 3A

 

 

 

 

 

 

 

 

 

 

 

 

36

 

Frequency

0 to 120Hz, - - -

0.1Hz

- - -

80

 

 

 

jump 3B

 

 

 

 

 

 

 

 

 

 

 

 

37

 

Speed display

0, 0.1 to 999

0.1

0

81

 

 

 

 

 

 

 

 

 

 

 

 

 

38

 

Frequency

1 to 120Hz

0.1Hz

60Hz

82

 

 

 

setting voltage

 

 

 

 

gain frequency

 

 

 

 

 

 

 

 

39

 

Frequency

1 to 120Hz

0.1Hz

60Hz

82

 

 

 

setting current

 

 

 

 

gain frequency

 

 

 

 

 

 

 

 

 

 

Start-time

0: Not detected

 

 

 

 

 

40

 

ground fault

1

0

86

 

 

 

detection

1: Detected

 

 

 

 

 

 

 

 

 

 

 

selection

 

 

 

 

 

 

 

50

Page 60
Image 60
Mitsubishi Electronics FR-S500 instruction manual Func Para Indica Name Setting Range, Tion