Explanation of functions (parameters)

2.3.4Multi-speed operation (Pr. 4 , Pr. 5 , Pr. 6 ,

Pr. 24 to Pr. 27 , Pr. 80 to Pr. 87 )

Used to switch between the predetermined running speeds.

Any speed can be selected by merely switching on/off the corresponding contact signals (RH, RM, RL, REX signals).

By using these functions with Pr. 1 "maximum frequency" and Pr. 2 "minimum frequency", up to 17 speeds can be set.

This function is valid in the external operation mode or in the combined operation mode which is available when Pr. 79 = "3" or "4".

(Hz)

 

Speed 1

 

 

 

 

 

 

 

 

 

 

 

 

 

(high speed)

Speed 5

frequency

 

 

 

 

Speed 2

 

 

(middle speed)

Speed 6

 

 

 

 

 

 

 

 

 

 

 

 

Speed 3

 

 

 

 

 

 

 

 

 

Speed 4

Output

 

 

 

(low speed)

 

 

 

 

 

 

 

 

 

Speed 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RH

 

 

 

ON

 

 

 

 

 

 

ON

ON

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RM

 

 

 

ON

 

ON

 

ON

ON

 

 

 

 

 

 

 

ON

ON

 

 

ON

 

 

 

 

 

 

 

 

 

 

RL

Priority: RL>RM>RH

REX

Output frequency (Hz)

RH

RM

RL

REX

Speed 10

Speed 11

 

Speed 9

Speed 12

 

Speed 13

 

 

 

 

Speed 8

 

 

 

Speed 14

 

 

 

 

 

 

Speed 15

Time

ON ON ON ON

ON ON ON ON

ON ON ON ON

ON ON ON ON ON ON ON ON

Parameter

Name

Factory

Setting

Remarks

Setting

Range

 

 

 

4

Multi-speed setting

60Hz

0 to 120Hz



(high speed)

 

 

 

 

5

Multi-speed setting

30Hz

0 to 120Hz



(middle speed)

 

 

 

 

6

Multi-speed setting

10Hz

0 to 120Hz



(low speed)

 

 

 

 

24 to 27

Multi-speed setting

- - -

0 to 120Hz,

"- - -" = no setting. Setting

 

(speeds 4 to 7)

 

- - -

enabled when Pr. 30 = "1".

80 to 87

Multi-speed setting

- - -

0 to 120Hz,

"- - -" = no setting. Setting

 

(speeds 8 to 15)

 

- - -

enabled when Pr. 30 = "1".

<Setting>

Set the running frequencies in the corresponding parameters.

Each speed (frequency) can be set as desired between 0 and 120Hz during inverter

operation.

 

When the parameter of any multi-speed setting is read, turn the

to change the

setting.

 

In this case, press the SET ( WRITE ) to store the frequency. (This is also enabled in the external mode.)

The setting is reflected by pressing the SET ( WRITE ).

Assign the terminals used for signals RH, RM, RL and REX using Pr. 60 to Pr. 63. (When terminal assignment is changed using Pr. 60 to Pr. 63, the other functions may be affected. Please make setting after confirming the function of each terminal.)

66

Page 76
Image 76
Mitsubishi Electronics FR-S500 Multi-speed operation Pr , Pr , Pr Pr to Pr , Pr to Pr, Name Factory Setting Remarks Range