2. Fire Prevention

CAUTION

￿Mount the inverter on an incombustible surface. Installing the inverter directly on or near a combustible surface could lead to a fire.

￿If the inverter has become faulty, switch off the inverter power. A continuous flow of large current could cause a fire.

￿Do not connect a resistor directly to the DC terminals P, N. This could cause a fire.

3.Injury Prevention

CAUTION

￿Apply only the voltage specified in the instruction manual to each terminal to prevent damage, etc.

￿Always connect to the correct terminal to prevent damage, etc.

￿Always make sure that polarity is correct to prevent damage, etc.

￿While power is on or for some time after power-off, do not touch the inverter as it is hot and you may get burnt.

4.Additional Instructions

Also note the following points to prevent an accidental failure, injury, electric shock, etc.

(1) Transportation and installation

CAUTION

￿When carrying products, use correct lifting gear to prevent injury.

￿Do not stack the inverter boxes higher than the number recommended.

￿Ensure that installation position and material can withstand the weight of the inverter. Install according to the information in the instruction manual.

￿Do not install or operate if the inverter is damaged or has parts missing.

￿When carrying the inverter, do not hold it by the front cover or setting dial; it may fall off or fail.

￿Do not stand or rest heavy objects on the inverter.

￿Check the inverter mounting orientation is correct.

￿Prevent other conductive bodies as screws and metal fragments or other flammable substance as oil from entering the inverter.

￿As the inverter is a precision instrument, do not drop or subject it to impact.

￿Use the inverter under the following environmental conditions: This could cause the inverter damage.

 

Ambient

-10°C to +50°C (14°F to 122°F) (non-freezing)

 

Temperature

Environment

 

Ambient humidity

90%RH maximum (non-condensing)

Storage

-20°C to +65°C (-4°F to 149°F) *

temperature

 

Atmosphere

Indoors (free from corrosive gas, flammable gas, oil mist,

dust and dirt)

 

 

Altitude/

Max.1000m (3280.80 feet) above sea level 5.9m/s2 or less

 

vibration

(conforming to JIS C 60068-2-6)

*Temperatures applicable for a short time, e.g. in transit.