Mitsubishi Electronics FR-S500 Parameter Instruction Code List, Display, Additional function

Models: FR-S500

1 196
Download 196 pages 9.03 Kb
Page 192
Image 192
Display

Parameter Instruction Code List

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instruction

Computer

Link Parameter

Func-

Parameter

Name

 

Code

Link Data

Extension Setting

tion

Number

 

Read

Write

Setting

(Instruction

 

 

 

 

 

 

 

 

 

Increments *

Code 7F/FF)

 

 

52

Operation panel display

 

34

B4

1

0

functions

 

data selection

 

 

54

 

36

B6

1

0

 

AM terminal function

 

 

 

53

Frequency setting

 

35

B5

1

0

 

 

operation selection

 

 

 

 

 

 

 

 

 

Display

 

 

selection

 

 

 

 

 

 

 

55

Frequency monitoring

 

37

B7

0.01Hz

0

 

 

reference

 

 

 

 

 

 

 

 

 

 

 

56

Current monitoring

 

38

B8

0.01A

0

 

 

reference

 

 

 

 

 

 

 

 

 

Automatic restart

functions

57

Restart coasting time

 

39

B9

0.1s

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

58

Restart cushion time

 

3A

BA

0.1s

0

 

 

 

 

 

 

 

 

 

Additional function

59

Remote setting function

 

3B

BB

1

0

 

 

 

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

RL terminal function

 

3C

BC

1

0

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

61

RM terminal function

 

3D

BD

1

0

 

 

selection

 

 

 

 

 

 

 

 

 

Terminal functions

selection

63

RH terminal function

 

3F

BF

1

0

selection

 

 

 

62

selection

 

3E

BE

1

0

 

 

 

STR terminal function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

64

RUN terminal function

 

40

C0

1

0

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

65

A, B, C terminal function

 

41

C1

1

0

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

66

Retry selection

 

42

C2

1

0

 

 

67

Number of retries at

 

43

C3

1

0

 

 

alarm occurrence

 

 

 

 

 

 

 

 

 

functions

 

68

Retry waiting time

 

44

C4

0.1s

0

 

71

Applied motor

 

47

C7

1

0

 

 

69

Retry count display erase

 

45

C5

1

0

 

 

70

Soft-PWM setting

 

46

C6

1

0

selection

 

74

Input filter time constant

 

4A

CA

1

0

 

 

72

PWM frequency selection

 

48

C8

1

0

 

 

73

0-5V/0-10V selection

 

49

C9

1

0

 

 

 

 

 

 

 

 

 

Operation

 

75

Reset selection/PU stop

 

4B

CB

1

0

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

76

Cooling fan operation

 

4C

CC

1

0

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

77

Parameter write disable

 

4D

None

1

0

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

78

Reverse rotation

 

4E

CE

1

0

 

 

prevention selection

 

 

 

 

 

 

 

 

 