Mitsubishi Electronics FR-S500 instruction manual Parameter List, Function Parameter list

Models: FR-S500

1 196
Download 196 pages 9.03 Kb
Page 64
Image 64
Function (Parameter) list

Parameter List

Function (Parameter) list

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Func- Para- Indica-

Name

Setting Range

Minimum

Factory Refer

Cus-

tion meter tion

Setting

Setting

To:

tomer

 

 

 

 

Increments

Setting

 

 

Presence/absence of

 

 

 

 

 

 

Soft-PWM control can

 

 

 

 

 

 

be selected.

 

 

 

 

 

 

When Soft-PWM is

 

 

 

 

 

Soft-PWM

valid, the metallic tone

1

1

103

 

70

of motor noise can be

 

setting

 

 

changed into

 

 

 

 

 

 

 

 

 

 

 

 

unoffending composite

 

 

 

 

 

 

tone.

 

 

 

 

0:Soft-PWM invalid

1:Soft-PWM valid

 

 

 

0, 100:

 

 

 

 

 

 

Thermal characteristic

 

 

 

 

 

 

for Mitsubishi

 

 

 

selectionOperation functions

 

 

standard motor

 

 

 

 

 

1, 101:

 

 

 

 

 

 

 

 

 

 

 

 

Thermal characteristic

 

 

 

 

71

Applied motor

for Mitsubishi

1

0

69

 

constant-torque motor

 

 

 

 

 

 

 

 

 

(Thermal characteristic

 

 

 

 

 

 

for Mitsubishi constant-

 

 

 

 

 

 

torque motor is

 

 

 

 

 

 

selected with the RT

 

 

 

 

 

 

signal ON when 100

 

 

 

 

 

 

and 101 are set.)

 

 

 

 

 

PWM

 

 

 

 

 

72

frequency

0 to 15

1

1

103

 

 

selection

 

 

 

 

 

73

0-5V/0-10V

0: For 0 to 5VDC input

1

0

104

 

selection

1: For 0 to 10VDC input

 

 

 

 

 

0:2-step moving average processing

74

Input filter

1 to 8:

1

1

105

time constant

Exponential

 

 

 

 

 

 

average value of 2n

 

 

 

 

 

at the setting of n

 

 

 

54

Page 64
Image 64
Mitsubishi Electronics FR-S500 instruction manual Parameter List, Function Parameter list, selectionOperation functions