2.9 Terminal function selection parameters

Terminal function selection parameters

CAUTION

The frequency can be varied by RH (acceleration) and RM (deceleration) between 0 and the maximum frequency (Pr. 1 setting).

When the acceleration or deceleration signal switches on, the set frequency varies according to the slope set in Pr. 44 "second acceleration/deceleration time" or Pr. 45 "second deceleration time". The output frequency acceleration and deceleration times are as set in Pr. 7 "acceleration time" and Pr. 8 "deceleration time", respectively. Therefore, the longer preset times are used to vary the actual output frequency.

If the start signal (STF or STR) is off, turning on the acceleration (RH) or deceleration (RM) signal varies the preset frequency.

2.9.1Input terminal function selection (Pr. 60 , Pr. 61 , Pr. 62 , Pr. 63 )Manual backgroundManual backgroundCAUTION

Manual background When selecting this function, re-set the maximum frequency according to the machine.

Related parameters

RH, RM, RL signal terminal assignment ⇒ Pr. 60 to Pr. 63 (input terminal function selection) (Refer to page 98.)

Maximum frequency setting ⇒ Pr. 1 "maximum frequency" (Refer to page 64.)

• Output frequency acceleration/deceleration time ⇒ Pr. 7

"acceleration time",

Pr. 8

"deceleration time" (Refer to page 67.)

Time setting for acceleration/deceleration ⇒ Pr. 44 "second acceleration/deceleration time", Pr. 45 "second deceleration time"

(Refer to page 67.)

2.9 Terminal function selection parameters

2.9.1Input terminal function selection (Pr. 60 Manual background, Pr. 61 Manual background, Pr. 62 Manual background, Pr. 63 Manual background)

Use these parameters to select/change the input terminal functions.

Parameter

Name

Factory

Setting Range

Remarks

Setting

 

 

 

 

60

RL terminal function

0

 

 

selection

 

 

 

 

 

 

61

RM terminal function

1

0 to 10, 14, 16

 

selection

Setting is enabled

 

 

 

62

RH terminal function

2

 

when Pr. 30 = "1"

selection

 

 

 

 

 

 

63

STR terminal function

- - -

0 to 10, 14, 16, - - -

 

selection

 

 

 

 

 

98