REMARKS

•When running two motors with one inverter, you can set the electronic thermal relay function of each inverter.

Pr. 71

First Motor Electronic Thermal Relay

Second Motor Electronic Thermal

 

Function

 

Relay Function

 

applied

Pr. 9

 

 

additional

 

 

motor

RT = OFF

RT = ON

parameter

RT = OFF

RT = ON

setting

 

 

 

H7 setting

 

 

 

 

 

 

 

 

 

0

 

 

- - -, 0

 

 

 

 

 

0.1 to 50A

 

standard

0

 

 

 

 

 

 

 

- - -

 

 

 

0.1 to 50A

standard

 

0

 

 

 

 

 

0.1 to 50A

 

standard

 

 

 

 

 

 

0

 

 

- - -, 0

 

 

 

 

 

0.1 to 50A

 

standard

1

 

 

 

 

 

 

 

- - -

 

 

 

0.1 to 50A

constant-

 

0

 

 

 

 

torque

 

0.1 to 50A

 

standard

 

0

 

 

- - -, 0

 

 

 

 

 

0.1 to 50A

 

constant-

 

 

 

 

 

torque

100

 

 

 

- - -

 

 

 

 

 

 

 

0.1 to 50A

 

 

0

 

 

 

standard

 

0.1 to 50A

 

constant-

 

 

 

 

 

 

 

 

 

torque

 

 

 

 

 

 

 

0

 

 

- - -, 0

 

 

 

 

 

0.1 to 50A

 

constant-

 

 

 

 

 

torque

101

 

 

 

- - -

 

 

 

 

 

 

 

0.1 to 50A

constant-

 

0

 

 

 

 

0.1 to 50A

 

constant-

 

 

torque

 

 

 

 

 

 

torque

 

 

 

 

 

 

standard

Thermal characteristic for

 

standard motor

constant-torque

Thermal characteristic for

 

constant-torque motor

Manual background ..... Output current value is used to

perform integration processing.

Manual background ..... Perform integration processing

using output current of 0A.

Manual background ..... Electronic thermal relay function

is not activated (cumulative value clear)

Manual backgroundManual backgroundManual backgroundCAUTION

Manual background Set this parameter correctly according to the motor used. Incorrect setting may cause the motor to overheat and burn.