Communication parameters

2.15.2 Operation and speed command source (n8 , n9 )

Used to make valid the operation and speed commands from the computer or external terminals.

Parameter

Name

Factory

Setting

Remarks

Setting

Range

 

 

 

n8 (338)

Operation

0

0, 1

 

command source

Setting is enabled when Pr. 30 = "1"

 

 

 

n9 (339)

Speed

0

0, 1

 

command source

 

 

 

 

 

The parameter numbers within parentheses are those for use of the parameter unit (FR-PU04).

<Setting>

In the computer operation mode, commands from the external terminals and computer are as listed below.

(Refer to page 98 for Pr. 60 to Pr. 63 (input terminal function selection).)

Operation

n8 (Pr. 338) "operation

0:

0:

1:

1:

 

command source"

Computer

Computer

External

External

Remarks

location

 

 

 

 

 

 

n9 (Pr. 339) "speed

0:

1:

0:

1:

selection

 

 

 

 

command source"

Computer

External

Computer

External

 

Fixed

 

Forward rotation command

Computer

Computer

External

External

 

 

(STF)

 

 

 

 

 

function

 

 

 

 

 

 

 

Computer link operation

Computer

 

Computer

 

 

(Terminal-

 

frequency

 

equivalent

 

 

 

 

 

 

 

 

2

External

External

 

function)

 

 

 

 

 

 

4

External

External

 

 

 

 

0

Low-speed operation

Computer

External

Computer

External

Pr. 59 = "0"

 

 

 

 

command (RL)

 

 

 

 

 

 

 

 

1

Middle-speed operation

Computer

External

Computer

External

Pr. 59 = "0"

 

 

 

command (RM)

 

 

 

2

High-speed operation

Computer

External

Computer

External

Pr. 59 = "0"

 

 

 

 

command (RH)

 

 

 

 

 

 

 

 

3

Second function

Computer

Computer

External

External

 

 

 

 

selection (RT)

 

 

 

63 settings

4

Current input selection

Combined

Combined

 

function

 

 

(AU)

 

 

 

 

 

 

5

Start self-holding

External

External

 

 

selection (STOP)

 

 

6

Output stop (MRS)

Combined

Combined

External

External

Pr. 79 ≠ "7"

Selection

 

60 to Pr.

 

 

 

 

 

 

 

 

7

External thermal relay

External

External

External

External

 

 

input (OH)

 

 

8

15-speed selection

Computer

External

Computer

External

Pr. 59 = "0"

 

 

Pr.

 

(REX)

 

 

 

 

 

 

 

9

Jog operation selection

External

External

 

 

 

 

 

 

 

 

(JOG)

 

 

 

 

10

Reset (RES)

External

External

External

External

 

 

 

 

14

PID control valid

Computer

External

Computer

External

 

 

 

 

 

terminal (X14)

 

 

 

 

 

 

 

 

16

PU-external operation

External

External

External

External

 

 

 

 

switch-over (X16)

 

 

 

 

---

Reverse rotation

Computer

Computer

External

External

 

 

 

 

 

command (STR)

 

 

 

 

 