1.5.4Start self-holding selection (STOP signal): Pr. 60 to Pr. 63

How to use the input signals (assigned terminals

RL, RM, RH, STR)

1.5.4Start self-holding selection (STOP signal): Pr. 60 to Pr. 63

setting "5"

This connection example is used when you want to self-hold the start signal (forward rotation, reverse rotation).

*Connected to the STOP signal to avoid forward or reverse rotation if forward or reverse rotation and stop are turned on simultaneously.

*

STOP

Stop

 

Forward

SD

 

rotation

 

Reverse

 

rotation

 

STF

STR

(Wiring example for sink logic)

1.5.5Output shut-off (MRS signal): Pr. 60 to Pr. 63 setting "6"

Short the output stop terminal MRS-SD during inverter output to cause the inverter to immediately stop the output. Open terminals MRS-SD to resume operation in about 10ms. Terminal MRS may be used as described below:

(1)

To stop the motor by

 

Motor coasted

 

 

mechanical brake (e.g.

frequency

 

 

to stop

 

 

electromagnetic brake)

 

 

 

 

 

 

 

Terminals MRS-SD must be

 

 

 

 

shorted when the mechanical

Output

 

Pr. 13

 

before motor restart.

 

 

brake is operated and be opened

 

0.5Hz

 

 

 

 

 

(2)

To provide interlock to

 

 

"starting

 

disable operation by the

Across

 

frequency"

 

inverter

ON

 

 

MRS -SD

 

 

After MRS-SD have been shorted,

Across

ON

 

 

the inverter cannot be operated if

STF-SD

 

 

 

 

 

the start signal is given to the

(STR)

 

 

 

inverter.

 

 

 

(3) To coast the motor to stop

The motor is decelerated according to the preset deceleration time and is stopped by operating the DC injection brake at 3Hz or less. By using terminal MRS, the motor is coasted to a stop.