Standardconnection diagramand terminal specifications

1.1Standard connection diagram and terminal specifications

1.1.1Standard connection diagram

￿Three-phase 200V power input

￿Three-phase 400V power input

NFB MC

Three-phase AC power supply

External transistor common 24VDC power supply Contact input common (source)

Take care not to short terminals PC-SD.

 

Forward rotation start

Control input

Reverse rotation start

signals

 

 

High speed

 

 

 

(No voltage

Multi-speed

Middle speed

input allowed)

selection

Low speed

 

 

 

 

Contact input common

Frequency setting signals (Analog)

Frequency setting

3

 

potentiometer

 

 

2

1/2W1k*4

 

 

 

Inverter

 

 

 

R/L1

 

 

U

 

Motor

 

 

 

IM

S/L2

 

 

V

 

T/L3

 

 

W

 

Ground

 

 

 

P1

 

 

 

 

 

 

PC

 

 

 

Power factor improving

 

 

 

 

DC reactor

 

 

 

 

(FR-BEL: Option)

 

 

 

P/+

Jumper: Remove this

 

 

 

 

 

 

 

 

jumper when FR-BEL

STF

 

*1 N/-

is connected.

 

 

 

 

 

STR *5

*2 PR

 

 

 

 

 

 

RH

*5

*6

A

 

 

 

 

 

 

RM

*5

*6

B

 

 

RL

*5

Alarm output

*6

C

SD

 

 

 

 

 

 

 

Operation status

 

 

*6 RUN

Running

 

 

output

 

 

 

 

 

 

 

 

SE

Open

Open collector

 

 

 

 

collector

outputs

10(+5V)

 

 

output

 

 

 

common

 

 

 

 

 

 

2 0 to 5VDC Selected 0 to 10VDC

1

Current input(-)

4 to 20mADC(+)

When using the current input as the frequency setting signal, set "4" in any of Pr. 60 to Pr. 63 (input terminal function selection), assign AU (current input selection) to any of terminals RH, RM, RL and STR and turn on the AU signal.

5

(Common)

4 (4 to 20mADC)

SINK

*3

SOURCE

RS-485

Connector

AM (+)

Analog signal output

(0 to 5VDC)

5 (-)

Ground

Main circuit terminal Control circuit terminal

REMARKS

*1. The N/- terminal is not provided for the FR-S520E-0.1K to 0.75K-NA.

*2. The PR terminal is provided for the FR-S520E-0.4K to 3.7K-NA. (not used)

*3. You can switch the position of sink and source logic. Refer to page 23.

*4. When the setting potentiometer is used frequently, use a 2W1kpotentiometer.

*5. The terminal functions change with input terminal function selection (Pr. 60 to Pr. 63). (Refer to page 98.) (RES, RL, RM, RH, RT, AU, STOP, MRS, OH, REX, JOG, X14, X16, (STR) signal selection)

*6. The terminal function changes according to the setting of output terminal function selection (Pr. 64, Pr. 65). (Refer to page 100.) (RUN, SU, OL, FU, RY, Y12, Y13, FDN, FUP, RL, Y93, Y95, LF, ABC signal selection)

CAUTION

To prevent a malfunction due to noise, keep the signal cables more than 10cm away from the power cables.

2

Page 12
Image 12
Mitsubishi Electronics FR-S500 instruction manual Standard connection diagram and terminal specifications, Nfb Mc, Stf