Mitsubishi Electronics FR-S500 Communication settings n1 to n7 , n11, Communication parameters

Models: FR-S500

1 196
Download 196 pages 9.03 Kb
Page 142
Image 142
2.15.1 Communication settings (n1  to n7 , n11 )

Communication parameters

2.15.1 Communication settings (n1  Communication-related parameters to n7 •Refer to page 180 for the instruction codes., n11  Communication specifications)

Manual background Communication-related parameters

Parameter

Name

Factory

Setting

Remarks

Reflection

Setting

Range

Timing

 

 

 

n1(331)

Communication station number

0

0 to 31

 

After reset

n2(332)

Communication speed

192

48,96,192

 

After reset

n3(333)

Stop bit length

1

0,1,10,11

 

After reset

n4(334)

Parity check presence/ absence

2

0,1,2

 

After reset

n5(335)

Number of communication

1

0 to 10,

Setting is enabled Immediately

retries

- - -

n6(336)

Communication check time

---

0, 0.1 to

when Pr. 30 = "1"

Immediately

interval (*)

999s, - - -

 

 

 

 

0 to

 

 

n7(337)

Waiting time setting

---

150ms,

 

After reset

 

 

 

- - -

 

 

n11(341)

CR/LF selection

1

0,1,2

 

After reset

The parameter numbers within parentheses are those for use of the parameter unit (FR-PU04).

Refer to page 180 for the instruction codes.

POINTS

*When making RS-485 communication, set any value other than 0 in the communication parameter n6 "communication check time interval". RS-485 communication is disabled if the setting is "0s".

Manual background Communication specifications

 

Item

Computer

Conforming standard

EIA-485 (RS-485)

Number of inverters

1:N (max. 32 inverters)

connected

 

Communication speed

Selected between 19200, 9600 and 4800bps

Control protocol

Asynchronous

Communication method

Half-duplex

Communication specifications

Character system

ASCII (7 bits/8 bits) selectable

 

Stop bit length

Selectable between 1 bit and 2 bits.

 

Terminator

CR/LF (presence/absence selectable)

 

Check

Parity check

Selectable between presence (even/odd) and absence

 

 

 

 

system

Sum check

Presence

 

 

 

 

Waiting

time setting

Selectable between presence and absence

REMARKS

•For computer link operation, set 65535 (HFFFF) as the value "- - -" and 65520 (HFFF0) as the Pr. 19 value "888".

•Refer to page 41 for handling the RS-485 connector.

•For parameter instruction codes, refer to the appended parameter instruction code list (page 180).