Communication parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instruction

 

 

 

Number

 

 

No.

Item

 

 

Description

of Data

 

 

Code

 

 

 

 

 

 

 

 

Digits

 

 

 

 

 

 

 

 

 

 

 

 

•When Pr. 37 = "0" (factory setting)

 

 

 

 

 

 

The set frequency (RAM or E2PROM) is read.

 

 

 

 

Set frequency

H6D

H0000 to H2EE0: 0.01Hz increments

 

 

 

 

•When Pr. 37 = "0.1 to 999", expansion link parameter

 

 

 

 

read (RAM)

 

 

 

 

 

(HFF) = 0

 

 

 

 

 

 

4 digits

 

 

 

 

 

The set speed is read.

 

 

 

 

H0000 to H03E7: 1r/min increments

(6 digits)

 

 

Set frequency

 

•When Pr. 37 = "0.1 to 999", expansion link parameter

 

 

 

 

 

(HFF) = 1

 

 

 

 

read

H6E

The set speed is read. (The number of data digits is 6

 

 

 

 

(E2PROM)

 

digits.)

 

 

 

 

 

 

H0000 to HF3E58: 0.001r/min increments

 

 

 

 

 

 

•When Pr. 37 = "0" (factory setting)

 

 

 

 

 

 

H0000 to H2EE0 (0 to 120.00Hz): Set frequency in

 

 

 

5

 

 

0.01Hz increments

 

 

 

 

 

When changing the set frequency continuously, write it

 

 

 

 

Set frequency

 

to the inverter RAM (instruction code: HED).

 

 

 

 

write

HED

The minimum setting increments are 0.01Hz but setting

 

 

 

 

(RAM only)

 

can be made in only 0.1Hz increments.

 

 

 

 

 

 

•When Pr. 37 = "0.1 to 999", expansion link parameter

 

 

 

 

 

 

HFF = 0

4 digits

 

 

 

 

H0000 to H03E7 (0 to 999): Set speed in 1r/min

(6 digits)

 

 

 

 

increments

 

 

 

 

 

 

•When Pr. 37 = "0.1 to 999", expansion link parameter

 

 

 

 

Set frequency

 

HFF = 1

 

 

 

 

 

H0000 to HF3E58 (0 to 999.000): Set speed in 0.001r/

 

 

 

 

write (RAM

HEE

min increments

 

 

 

 

and E2PROM)

 

Set the number of data digits as 6 digits.

 

 

 

 

 

 

The minimum setting increments are 0.001r/min but

 

 

 

 

 

 

setting can be made in only 0.01r/min increments.

 

 

 

 

 

 

H9696: Resets the inverter.

 

 

 

6

Inverter reset

HFD

As the inverter is reset on start of communication by the

4 digits

 

 

 

 

computer, the inverter cannot send reply data back to the

 

 

 

 

 

 

computer.

 

 

 

 

Alarm

 

 

 

 

 

 

 

7

definition

HF4

H9696: Alarm history batch clear

4 digits

 

 

batch clear

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUNCTIONS

143

Page 153
Image 153