2.9.2Output terminal function selection (Pr. 64 , Pr. 65 )

Terminal function selection parameters

2.9.2Output terminal function selection (Pr. 64 Manual background, Pr. 65 Manual background)

You can change the functions of the open collector output terminal and contact output terminal.

Parameter

Name

Factory

Setting Range

Remarks

Setting

 

 

 

 

64

RUN terminal function

0

0, 1, 3, 4, 11 to

 

selection

16, 93, 95, 98, 99

Setting is enabled

 

 

 

 

 

 

when Pr. 30 = "1"

65

A, B, C terminal function

99

0, 1, 3, 4, 11 to

selection

16, 95, 98, 99

 

 

 

 

<Setting>

Setting

Signal

Function

Operation

Parameters

Name

Referred to

 

 

 

 

 

 

Output during operation when the

 

0

RUN

Inverter running

inverter output frequency rises to

Pr. 2, Pr. 13

 

 

 

or above the starting frequency.

 

1

SU

Up to frequency

Output when the output frequency

Pr. 41

 

 

 

is reached.

 

3

OL

Overload alarm

Output while stall prevention

Pr. 21, Pr. 22,

function is activated.

Pr. 23, Pr. 28

 

 

 

4

FU

Output frequency

Output when the output frequency

Pr. 42, Pr. 43

 

 

detection

rises to or above the setting.

 

 

 

Inverter operation

Output when the inverter is ready

 

11

RY

to be started by switching the

ready

 

 

start signal on.

 

 

 

 

 

12

Y12

Output current

Output when the output current

Pr. 48, Pr. 49

detection

rises to or above the setting.

 

 

 

13

Y13

Zero current detection

Output when the output current

Pr. 50, Pr. 51

 

 

 

reaches 0.

 

14

FDN

PID lower limit

Outputs the detection signal

 

15

FUP

PID upper limit

Pr. 88 to Pr. 94

 

 

 

under PID control.

16

RL

PID forward-reverse

 

rotation output

 

 

 

 

 

 

 

 

 

The output current average value

 

 

 

Current average value

and maintenance timer value are

 

93

Y93

output during the constant speed

H3 to H5

 

 

monitor signal

operation. (can be set to the RUN

 

 

 

 

 

 

 

 

terminal (Pr.64) only)

 

 

 

Maintenance timer

Output when maintenance

 

95

Y95

parameter H1 is greater than

H1, H2

alarm

 

 

maintenance parameter H2.

 

 

 

 

 

 

 

 

Output when a minor fault (fan

 

98

LF

Minor fault output

failure or communication error

Pr. 76, n5

 

 

 

warning) occurs.

 

 

 

 

Output when the inverter's

 

99

ABC

Alarm output

protective function is activated to

 

 

 

stop the output (major fault).

 

REMARKS

One function can be assigned to two terminals.

100

Page 110
Image 110
Mitsubishi Electronics FR-S500 instruction manual Output terminal function selection Pr. 64 , Pr, Setting