Mitsubishi Electronics FR-S500 Function Parameter list, Parameter List, functions, Functions

Models: FR-S500

1 196
Download 196 pages 9.03 Kb
Page 59
Image 59
functions

Function (Parameter) list

The extended function parameters are made valid by setting "1" in Pr. 30 "extended function display selection". (For more detailed information on the way to set Pr. 30, refer to the instruction manual (basic).)

Func- Para- Indica-

Name

Setting Range

Minimum

Factory Refer

Cus-

tion meter tion

Setting

Setting To:

tomer

 

 

Increments

Setting

Parameters 0 to 9 are basic function parameters.

 

 

 

DC injection

 

 

 

 

 

 

10

 

brake

0 to 120Hz

0.1Hz

3Hz

71

 

 

 

operation

 

 

 

 

 

 

 

 

 

 

 

 

frequency

 

 

 

 

 

 

11

 

DC injection

0 to 10s

0.1s

0.5s

71

 

 

 

brake

 

 

 

 

operation time

 

 

 

 

 

 

12

 

DC injection

0 to 15%

0.1%

6%

71

 

 

 

brake voltage

 

 

13

 

Starting

0 to 60Hz

0.1Hz

0.5Hz

72

 

 

 

frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

0: For constant-torque

 

 

 

 

 

 

 

Load pattern

loads,

 

 

 

 

 

14

 

1: For variable-torque

1

0

73

 

 

 

selection

loads,

 

 

 

 

 

 

 

 

 

 

 

 

2: For vertical lift loads,

 

 

 

 

 

 

 

 

3: For vertical lift loads

 

 

 

 

functions

16

 

acceleration/

0 to 999s

0.1s

0.5s

74

 

 

15

 

Jog frequency

0 to 120Hz

0.1Hz

5Hz

74

 

 

 

 

Jog

 

 

 

 

 

operation

 

 

deceleration

0: Forward rotation,

 

 

 

 

 

 

rotation

 

 

 

 

 

 

 

time

 

 

 

 

 

 

 

 

RUN key

 

 

 

 

 

Standard

17

 

direction

1: Reverse rotation

1

0

74

 

19

 

1V

- - -

65

 

 

voltage

0 to 800V, 888, - - -

 

 

 

 

selection

 

 

 

 

 

 

 

 

Basefrequency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Acceleration/

 

 

 

 

 

 

20

 

deceleration

1 to 120Hz

0.1Hz

60Hz

67

 

 

 

reference

 

 

 

 

 

 

 

 

 

 

 

 

frequency

 

 

 

 

 

 

 

 

Stall

 

 

 

 

 

 

21

 

prevention

0 to 31, 100

1

0

75

 

 

 

function

 

 

 

 

 

 

 

 

 

 

 

 

selection

 

 

 

 

 

 

 

 

Stall

 

 

 

 

 

 

22

 

prevention

0 to 200%

1%

150%

77

 

 

 

operation

 

 

 

 

 

 

 

 

 

 

 

 

level

 

 

 

 

 

 

 

 

Stall

 

 

 

 

 

 

 

 

prevention

 

 

 

 

 

 

23

 

operation level

0 to 200%, - - -

1%

- - -

77

 

 

 

 

compensation

 

 

 

 

 

 

 

 

factor at

 

 

 

 

 

 

 

 

double speed

 

 

 

 

 

Parameter List

2

FUNCTIONS

49

Page 59
Image 59
Mitsubishi Electronics FR-S500 instruction manual Function Parameter list, Parameter List, functions, Functions