Mitsubishi Electronics FR-S500 PU contrast adjustment n15, Setting, During stop, During operation

Models: FR-S500

1 196
Download 196 pages 9.03 Kb
Page 162
Image 162
2.16.3 PU contrast adjustment (n15 )

Parameter unit (FR-PU04) setting

2.16.3 PU contrast adjustment (n15 2.16.4 PU main display screen data selection (n16 ))

By setting the communication parameter n15 "PU contrast adjustment", you can adjust the LCD contrast of the parameter unit (FR-PU04). When using the FR-

PU04, adjust the numerical value to any darkness with the During stop/During operation and define that brightness with the WRITE of the parameter unit.

Parameter

Name

Factory

Setting

Remarks

Setting

Range

 

 

 

n15 (991)

PU contrast adjustment

58

0 to 63 Setting is enabled when Pr. 30 = "1"

The parameter number in parentheses is the one for use with the parameter unit (FR- PU04).

CAUTION

When using the FR-PU04, you should press the WRITE to store the PU contrast setting value.

2.16.4 PU main display screen data selection (n16 Manual background)

You can choose the main display screen of the parameter unit (FR-PU04).

Parameter

Name

Factory

Setting

Remarks

Setting

Range

 

 

 

 

PU main display

 

 

 

n16 (992)

screen data

0

0, 100 Setting is enabled when Pr. 30 = "1"

 

selection

 

 

 

The parameter number in parentheses is the one for use with the parameter unit (FR- PU04).

<Setting>

When "100" is set in n16, the monitor value is different depending on whether the inverter is at a stop or running.

 

0

n16

100

 

 

 

During operation/stop

During stop

During operation

Output frequency

Output frequency

Set frequency

Output frequency

Output current

 

Output current

 

Alarm display

 

Alarm display

 

REMARKS

•During an error, the output frequency at error occurrence appears.

•During MRS, the values displayed are the same as during a stop.

Related parameters

•Speed display Pr. 37 "speed display" (refer to page 81)

152

Page 162
Image 162
Mitsubishi Electronics FR-S500 PU contrast adjustment n15, PU main display screen data selection n16, Setting, During stop