Communication parameters

<Setting>

n10

Pr. 79

Operation Mode at

 

Power on or Power

Remarks

Setting

Setting

Restoration

 

 

 

 

 

0

External operation mode

Can be changed to the computer link operation

 

mode by RS-485 communication.

 

1

PU operation mode

Operation mode cannot be changed.

 

2

External operation mode

Can be changed to the computer link operation

 

 

 

mode by RS-485 communication.

 

3

External/PU combined

 

 

mode

Operation mode cannot be changed.

 

 

 

4

External/PU combined

 

 

0

mode

 

 

 

 

 

MRS signal ON.....Can be changed to PU

(Factory

 

 

 

 

operation by RS-485

setting)

 

External operation mode

7

communication.

 

(PU operation interlock)

 

 

MRS signal OFF...Operation mode cannot be

 

 

 

 

 

 

changed.

 

 

•X16 signal ON

Can be changed to the computer link operation

 

 

Started in the external

 

 

mode by RS-485 communication.

 

8

operation mode.

 

 

 

•X16 signal OFF

 

 

 

 

 

 

Started in the PU

Operation mode cannot be changed.

 

 

operation mode.

 

 

0

Computer link operation

Can be changed to the external operation mode

 

mode

by RS-485 communication.

 

 

 

1

PU operation mode

Operation mode cannot be changed.

 

2

Computer link operation

Can be changed to the external operation mode

 

mode

by RS-485 communication.

 

 

 

3

External/PU combined

 

 

mode

Operation mode cannot be changed.

 

 

 

4

External/PU combined

 

 

 

mode

 

 

 

 

 

 

PU operation interlock

Can be changed to external operation by RS-

1

 

•MRS signal ON

 

Started in the computer

485 communication.

 

 

 

7

link operation mode.

 

 

 

•MRS signal OFF

 

 

 

Started in the external

Operation mode cannot be changed.

 

 

operation mode.

 

 

 

•X16 signal ON

Can be changed to external operation by RS-

 

 

Started in the computer

 

 

485 communication.

 

8

link operation mode.

 

 

•X16 signal OFF

 

 

 

 

 

 

Started in the PU

Operation mode cannot be changed.

 

 

operation mode.

 

n10 can be changed independently of the operation mode of the operation panel.

Setting of n10 = "1" is made valid when "0" or "2" is set in Pr. 79 "operation mode selection".

Manual backgroundManual background Refer to Manual background to Manual background(page 132)