Mitsubishi Electronics FR-S500 Jog operation Pr.15 , Pr.16, 2.3.11, using the FWD or REV

Models: FR-S500

1 196
Download 196 pages 9.03 Kb
Page 84
Image 84
2.3.10 Jog operation (Pr.15 , Pr.16 )

Explanation of functions (parameters)

2.3.10 Jog operation (Pr.15 using the FWD or REV ., Pr.16 2.3.11)

To start/stop jog operation in the external operation mode, choose the jog operation function in input terminal function selection, turn on the jog signal, and turn on/off the start signal (STF, STR).

You can choose the jog operation mode from the parameter unit (FR- PU04) and perform jog operation

using the FWD or REV .

Output frequency (Hz) Pr.20

Jog frequencyRUN key rotation direction selection (Pr.17 setting range Manual background

Pr.15

JOG signal

STF signal

ForwardManual background rotation Manual background

Pr.16

ON

ON

(Can be read as the basic parameters when the FR-PU04 is connected.)

Manual background Set the frequency and acceleration/deceleration time for jog operation.

Parameter

Name

Factory Setting

Setting Range

Remarks

15

Jog frequency

5Hz

0 to 120Hz

Setting is enabled when

 

Jog acceleration/

 

 

16

0.5s

0 to 999s

Pr. 30 = "1".

deceleration time

 

 

 

 

CAUTION

In S-shaped acceleration/deceleration pattern A, the acceleration/deceleration time is the period of time required to reach Pr. 3 "base frequency", not Pr. 20 "acceleration/deceleration reference frequency".

The acceleration time and deceleration time cannot be set separately for jog operation.

The Pr. 15 "Jog frequency" value should be equal to or higher than the Pr. 13 "starting frequency" setting.

Assign the jog signal using any of Pr. 60 to Pr. 63 (input terminal function selection).

Related parameters

Assignment of jog signal to terminal ⇒ Pr. 60 to Pr. 63 (input terminal function selection) (refer to page 98)

Acceleration/deceleration pattern S-shaped acceleration/deceleration A

Pr. 29 "acceleration/deceleration pattern" (refer to page 79)

2.3.11

RUN key rotation direction selection (Pr.17

)

 

Used to choose the direction of rotation by operating the RUN key of the operation

 

 

panel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Name

Factory

Setting

Remarks

 

 

Setting

Range

 

 

 

 

 

 

 

 

17

RUN key rotation

0

0, 1

0: Forward rotation

Setting is enabled

 

direction selection

1: Reverse rotation

when Pr. 30 = "1".

 

 

 

 

Manual backgroundManual background Refer to Manual background (page 65)

Manual backgroundManual background Refer to Manual background , Manual background (page 67)

74

Page 84
Image 84
Mitsubishi Electronics FR-S500 Jog operation Pr.15 , Pr.16, 2.3.11, RUN key rotation direction selection Pr.17