Explanation of functions (parameters)

2.3.10 Jog operation (Pr.15 , Pr.16 )

To start/stop jog operation in the external operation mode, choose the jog operation function in input terminal function selection, turn on the jog signal, and turn on/off the start signal (STF, STR).

You can choose the jog operation mode from the parameter unit (FR- PU04) and perform jog operation

using the FWD or REV .

Output frequency (Hz) Pr.20

Jog frequency setting range

Pr.15

JOG signal

STF signal

Forward rotation

Pr.16

ON

ON

(Can be read as the basic parameters when the FR-PU04 is connected.)

Set the frequency and acceleration/deceleration time for jog operation.

Parameter

Name

Factory Setting

Setting Range

Remarks

15

Jog frequency

5Hz

0 to 120Hz

Setting is enabled when

 

Jog acceleration/

 

 

16

0.5s

0 to 999s

Pr. 30 = "1".

deceleration time

 

 

 

 

CAUTION

In S-shaped acceleration/deceleration pattern A, the acceleration/deceleration time is the period of time required to reach Pr. 3 "base frequency", not Pr. 20 "acceleration/deceleration reference frequency".

The acceleration time and deceleration time cannot be set separately for jog operation.

The Pr. 15 "Jog frequency" value should be equal to or higher than the Pr. 13 "starting frequency" setting.

Assign the jog signal using any of Pr. 60 to Pr. 63 (input terminal function selection).

Related parameters

Assignment of jog signal to terminal ⇒ Pr. 60 to Pr. 63 (input terminal function selection) (refer to page 98)

Acceleration/deceleration pattern S-shaped acceleration/deceleration A

Pr. 29 "acceleration/deceleration pattern" (refer to page 79)

2.3.11

RUN key rotation direction selection (Pr.17

)

 

Used to choose the direction of rotation by operating the RUN key of the operation

 

 

panel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Name

Factory

Setting

Remarks

 

 

Setting

Range

 

 

 

 

 

 

 

 

17

RUN key rotation

0

0, 1

0: Forward rotation

Setting is enabled

 

direction selection

1: Reverse rotation

when Pr. 30 = "1".

 

 

 

 

Refer to (page 65)

Refer to , (page 67)