Mitsubishi Electronics FR-S500 instruction manual Starting frequency Pr, rangeSetting

Models: FR-S500

1 196
Download 196 pages 9.03 Kb
Page 82
Image 82
2.3.8Starting frequency (Pr. 13 )

Explanation of functions (parameters)

2.3.8Starting frequency (Pr. 13 rangeSetting)

The starting frequency at which the start signal is turned on can be set in the range 0 to 60Hz.

Output frequency

 

 

 

rangeSetting

(Hz)

60

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.13

 

 

0

 

 

Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency setting signal (V)

Foward rotation

ON

Parameter

Name

Factory

Setting

Remarks

Setting

Range

 

 

 

13

Starting frequency

0.5Hz

0 to 60Hz

Setting is enabled when Pr. 30 = "1".

CAUTION

The inverter will not start if the frequency setting signal is less than the value set in Pr. 13 "starting frequency".

For example, when 5Hz is set in Pr. 13, the motor will not start running until the frequency setting signal reaches 5Hz.

Manual backgroundCAUTION

Note that when Pr. 13 is set to any value lower than Pr. 2 "minimum frequency", simply turning on the start signal will run the motor at the preset frequency even if the command frequency is not input.

Related parameters

Minimum frequency setting ⇒ Pr. 2 "minimum frequency" (refer to page 64)

72