Mitsubishi Electronics FR-S500 instruction manual Acceleration/deceleration pattern Pr, Setting

Models: FR-S500

1 196
Download 196 pages 9.03 Kb
Page 89
Image 89
2.3.14 Acceleration/deceleration pattern (Pr. 29 )

Explanation of functions (parameters)

2.3.14 Acceleration/deceleration pattern (Pr. 29 Set the acceleration/deceleration pattern.)

Set the acceleration/deceleration pattern.

 

Set value 0

 

Set value 1

 

[Linear

 

[S-pattern

 

acceleration/deceleration]

acceleration/deceleration A]

(Hz)

 

(Hz)

 

 

Output frequency

 

Output frequency

fb

 

 

 

 

 

 

Time

 

 

Time

Set value 2

[S-pattern acceleration/deceleration B]

(Hz)f1

 

 

 

 

 

 

 

 

Output frequency

 

 

 

 

f2

 

 

Time

 

 

 

Parameter

Name

Factory

Setting

Remarks

Setting

Range

 

 

 

29

Acceleration/

0

0, 1, 2

Setting is enabled when Pr. 30 = "1".

deceleration pattern

 

 

 

 

<Setting>

 

 

 

 

 

 

 

 

Pr. 29

Function

 

 

Description

Setting

 

 

 

 

 

 

 

Linear

Acceleration is made to the set frequency linearly.

0

acceleration/

(Factory setting)

 

 

deceleration

 

 

 

 

 

 

 

 

 

 

For machine tool spindle applications, etc.

 

 

Used when acceleration/deceleration must be made in a short

 

S-pattern

time to a high-speed region of not lower than the base

 

frequency. Acceleration/deceleration is made in a pattern

1

acceleration/

where fb (base frequency) acts as the inflection point of an S

 

deceleration A (*)

 

shape, and you can set the acceleration/deceleration time

 

 

which matches the motor torque reduction in the constant-

 

 

output operation region of not lower than the base frequency.

 

S-pattern

For prevention of load shifting in conveyor and other

 

applications. Since acceleration/deceleration is always made in

2

acceleration/

an S shape from f2 (current frequency) to f1 (target frequency),

 

deceleration B

this function eases shock produced at acceleration/

 

 

deceleration and is effective for load collapse prevention, etc.

CAUTION

2

*As the acceleration/deceleration time, set the time taken to reach the Pr. 3 "base frequency" value, not the Pr. 20 "acceleration/deceleration reference frequency" value.

Related parameters

Base frequency (acceleration/deceleration time setting) setting ⇒ Pr. 3 "base frequency" (refer to page 65)

Pr. 20 "acceleration / deceleration reference frequency" ⇒ refer to page 67

For setting of "1" (S-pattern acceleration/deceleration A)

Pr. 44 "second acceleration/deceleration time", Pr. 45 "second deceleration time" (refer to page 67)

FUNCTIONS

79

Page 89
Image 89
Mitsubishi Electronics FR-S500 Acceleration/deceleration pattern Pr, Setting, Set the acceleration/deceleration pattern