Casio IT-2000 installation manual Can I update the version of Master I/O Box firmware ?

Page 28
Can I update the version of Master I/O Box firmware ?

Q2

What is the maximum baud rate if the Satellite I/O Boxes are connected under daisy-chain so they follow each Master I/O Box ?

A2

In this case the physical Master I/O Box-to-Satellite I/O Box speed is 115200 bps max.

Q3

Can I update the version of Master I/O Box firmware ?

A3

Yes, by using the dedicated download tool and a SCSI cable. Your nearest support/technical center will inform you if it is necessary.

Q4

What happens if the power to a middle Master I/O Box which is connected to the PC is turned OFF ?

A4

The Master I/O Box that is turned OFF and all Satellite I/O Boxes that are connected to that Master I/O Box are communication-disabled. Communication with Master I/O Boxes, other than with that which is turned OFF, is permitted. To make the Master I/O Box available again, turn ON that Master I/O Box first, then restart the PC.

Q5

If an attempt was made to execute the Upload/Download Utility, a startup error appeared. Why?

A5

A startup error occurs if the SCSI cable is not properly plugged in or if the power to all the Master I/O Boxes is not on.

Q6

If multiple Master I/O Boxes are connected, can each IT-2000 terminal independently use either the MS-DOS version of FLINK or the Windows3.1 version of FLINK ?

A6

This is not permitted. A timeout error will occur because of a timing lag between the MS-DOS version of FLINK and the Windows3.1 version of FLINK.

28

Image 28
Contents April Copyright 1998. All rights reservedIT-2000 I/O Box Installation Manual VersionTable of Contents Appendix1. Overview 2.1 Options and Software 2. System Configuration and Installation MethodSoftware 2.2.1 With Single I/O Box 2.2 System Configuration2.2.2 With Multiple I/O Boxes 2.2.3 With Single Master I/O Box 2.2.4 With Multiple Master I/O Boxes2.2.5 With Master and Satellite I/O Boxes 2.3 Installation Method With single Satellite I/O Box 2.3.1 Setup of Satellite I/O BoxWith Multiple Satellite I/O Boxes I/O Box This is for the termination 2.3.2 Setup of Master I/O Box 2.3.3 Setup of Satellite I/O Box to Master I/O Box Connection 2.3.4 Setup of PCStartup Environment Setup 3. Operation Method 3.1 File Upload3.1.1 Specifying Files from PC Operation on PCFLINK.DLL of Windows 3.1 version Operation on IT-2000DoFLINK argc, argv argc = argv = fl 3.1.2 Specifying Files from IT-2000 FLINK.EXE of MS-DOS versionFLINK.DLL of Windows 3.1 version 3.2 File Download 3.2.1 Specifying Files from PCFLINK.EXE of MS-DOS version 3.2.2 Specifying Files from IT-2000 FLINK /R CFILE DDoFLINK argc, argv argc = argv = fl , /r, CFILE, Dyyy 4. Error Codes and Error Messages Categ DetaiTable 4.2 Error codes and error messages Common to Satellite and Master I/O Boxes 5. Q and ASatellite I/O Box Master I/O Box Can I update the version of Master I/O Box firmware ? IT-2000 Upload/Download Utility Manual 6. Reference ManualsIT-2000 Technical Reference Manual IT-2000 Hardware Manual SCSI Board 7. List of SCSI Boards and SCSI CablesSCSI Cable Appendix Installation Method of Upload/Download Utility InstallationSyntax of the Installer Command setup