Casio PA-2400W manual Error Code Meaning Possible Cause Remedy

Page 55

Table 7.6 List of termination codes

Error Code

Meaning

Possible Cause

Remedy

Category

Detail

 

 

 

code

code

 

 

 

00h

00h

Normally terminated

Normal.

-

DCh to

00h

Normally terminated

Formatting of drive a:between 'A'

Refer to Chapter 7.5

F5h

 

 

and 'Z' is specified from the

“Restrictions”.

 

 

 

partner station. (For drive letter

 

 

 

 

definitions, refer to Chapter

 

 

 

 

7.7 “Method of Describing

 

 

 

 

Pathname”.)

 

F6h

00h

Normally terminated

Power-off is specified from the

Turn off the power.

 

 

 

partner station.

 

F7h

00h

Normally terminated.

Resetting the power is specified

Refer to Chapter 7.5

 

 

 

from the partner station.

“Restrictions”.

F8h

00h

Terminated due to interruption.

Communication is terminated

Resume communication as

 

 

 

because the break key is pressed

required.

 

 

 

on the PA-2400W (local station)

 

 

 

 

or partner station.

 

01h

00h

Protocol error

Data anomaly (data error

Check the communication

 

 

 

occurred on the communication

line connection.

 

 

 

line).

 

02h

80h

File not found

Non-existent file is specified.

Check the specified file or

 

 

 

 

directory.

02h

81h

Current directory delete error

An attempt has been made to

Check the objective

 

 

 

delete the current directory.

directory of deletion.

02h

82h

File write error

Write to the file is not possible.

Check if the file is ready to

 

 

 

 

be written.

02h

83h

File read error

Read from the file is not possible.

Check if the file is ready to

 

 

 

 

be read from.

02h

84h

Read only access error

An attempt has been made to

Specify another file name or

 

 

 

overwrite or delete the read-only

cancel the read-only

 

 

 

file.

attribute.

0Fh

01h

Argument parameter error

Incorrect argument description

Check the argument

 

 

 

 

parameter.

0Fh

02h

Argument too long

Argument portion of the

Reduce the length of the

 

 

 

command line is too long

argument including FLCE to

 

 

 

 

255 characters or less.

A0h

10h

Communication port open error

One of the other programs is

Terminate the program that

 

 

 

using COM1 or IrDA,or FLCE is

is using COM1 or IrDA.

 

 

 

already initiated.

 

A0h

20h

Line break error or IrDA

Either the cable was unplugged

Check the cable connection

 

 

duplicate open error

during communication or the

and mounting condition of

 

 

 

IrDA connection is broken

the PA-2400W on I/O Box.

 

 

 

(where the PA-2400W is

 

 

 

 

dismounted from I/O Box).

 

 

 

 

IrDA port is already open.

Terminate the other

 

 

 

 

program that is using IrDA.

A0h

30h

Session-wait timeout error

Session was not established

Check the cable connection

 

 

 

within 1 minute of startup.

or check if the IrDA is ready

 

 

 

 

for communication.

55

Image 55
Contents Version PA-2400W Library ManualTable of Contents Fchkce /G Fchkce /C Casio PrefaceSIPanel Library Bootup LibrarySupported Files System LibraryHost PC PA-2400W Copy System configurationDedicated Library and Utility System Library 3 I/O Bootup LibrarySIPanel Library File Check Utility File Transfer UtilityDevelopment Environment System Library Overview Header #include CasioSys.h Remarks Details of FunctionTitle Function Parameters None Return ValuesTurns off the backlight Language Interface Calling Sequence Backlight is off TrueBacklight is on FalseHeader #include CasioSys. h Remarks DisablePowerOff Bool EnablePowerOff Enable the power to be turned off with the power button Disable the power to be turned off with the power buttonHeader Bool ApoCountReset Void SoftReset Parameters Bool bMode Disables automatic power-on with the alarmInternal error Language Interface Calling SequenceBool GetPowerOnAlarm Default Sample program to acquire power-on event notification Bool GetPowerEventStat SIPANEL.DLL SIPanel Library OverviewSIPANEL.EXE Registry Use of SIPanel LibraryRestrictions Program for starting up the libraryLpctstr lpParam Siphide SipshowSample program to start up the SIPanel Lptstr HinstanceHbCallText = CreateWindow TEXTbutton, TEXTText Area Sample program of application software for business useTchar ClassName = Text CallSip Tchar ClassNameTSR = TEXTSipTsrWsvisible Wsoverlapped Wssysmenu HWnd = CreateWindowClassName, ClassNameLpCmdLine Find SipTsr Px,y Options of Command LineSw,h Port O Bootup Library OverviewFunction IOBOX1.DLLFail to call the function Infinite = No timeoutDword 294,967,295 msec. equals to InfiniteMultiple-Thread Mode Sequential ModeUse of ioboxchk Hwnd Sample Program= Null Null WsoverlappedWINDOWWIDTH/2 WINDOWHEIGHT/2Case Wmpaint Wait for 5 seconds Enable the power on event notification Disable the power on by alarmRegistry of Libraries RS-232C Interface File Transfer Utility OverviewIrDA 1.0 Interface List of Supported Commands Input Parameter Use of FlceTermination of Flce OperationRestrictions Overwrite Communication CommandsOptions Types of ArgumentsMethod of Describing Pathname Storage Card PC card My Documents Internal RAM ReferenceWindows CE Windows95 /Windows NT Required Error if omittedSpecifying Non-existing File DOSSetting Up Items Setting Up Registry Dword Disp1 Setting Up Registry with User Application Hkey hKey1 Long lReg1Return err Err=FALSE Else If err==TRUEShould take an action that is appropriate to each definition Termination CodesError Code Meaning Possible Cause Remedy Method of Creation Log FileLog File Name Location of Log File12Precautions Details of Command and Option Flce /SR \casio\*.dat d\casiodat\ Transmission file pathnameDestination directory pathname Flce /S \casio\*.dat d\casiodat\Flce /RR a\12\*.dat d\casio\*.* \casio data\ PathnamePathname of requested file \12\*.dat d\casio\*.* \casio data\Target file pathname Appended file pathnameFlce /A \MY\casio.dat b\your\master.dat Pathname of file to be deleted Without the R option Flce /N a\12\kk.dat a\casio\sj.dat Source pathnameDestination pathname Flce /N a\ 12\kk.dat a\casio\Flce /SR \casio ap\*.* \casio ap\ /T Parameters None SetupExampleSession between PA-2400W-and-PA-2400W Session with PCFlce casio.scr Flce /Y=COM1, , casio.scrIdle notification Command and Status\soft\ Retry Process When Downloading FileRetry Method Preparation at PCPreparation at PA-2400W RestrictionRetry.scr File Check Utility Overview List of CommandsDownloading file from PC to PA-2400W Operation MethodOperation Transmission side PA-2400W Copying file with PC card from PA-2400W to PA-2400WCopy PC card Describing Method 1Pathname Example of Incorrect Startup no /G or /C option Details about Command and OptionExamples of specification for command and option Examples of Correct StartupCommand of Fchkce 1Generation of List File Comparison by List File FILENO=3 \AP\MENU.EXE 12345 \CONFIG.SYS 1000 \AUTOEXEC.BAT 512Format of List File ExampleChildproccmd = C Syntax Analysis of Script FileOption = Recursiveoption Updateoption Recursiveoption = R Error Messages/Codes Restriction File name list or Script file name Option /SCSpecification of a script file nameSpecification of recursive call AO Append outputFchkce /G /R \casio\ .dat \casio data\ \casio\ Destination directory nameFCHK.LOG file output directory name \casio\ .dat \casio data\ \casio\Fchkce /C \casio data\ Does not compare the update dataOption FCHK.LOG file pathname