Casio PA-2400W manual Parameters None SetupExample, Flce /SR \casio ap\*.* \casio ap\ /T

Page 64

Title

 

Command

FLCE /T

This command transfers the system date and time of the PA-2400W to the communication partner side for setting.

￿Transmitted date and time is a local time.

Depending on the line condition, a few seconds of error may result.

C Language Interface￿

Calling Sequence￿

FLCE /T

Parameters￿

￿None

Setup￿Example￿

FLCE /SR "\casio ap\*.*" "\casio ap\" /T

Transfers all files under the "casio ap" directory (including sub-directories) of the PA-2400W to the "\casio ap\" directory of the communication partner side for setting up.

64

Image 64
Contents PA-2400W Library Manual VersionTable of Contents Fchkce /G Fchkce /C Preface CasioBootup Library Supported FilesSystem Library SIPanel LibrarySystem configuration Host PC PA-2400W CopyDedicated Library and Utility System Library 3 I/O Bootup LibrarySIPanel Library File Transfer Utility File Check UtilityDevelopment Environment System Library Overview Details of Function Title FunctionParameters None Return Values Header #include CasioSys.h RemarksTurns off the backlight Language Interface Calling Sequence True Backlight is onFalse Backlight is offHeader #include CasioSys. h Remarks DisablePowerOff Bool EnablePowerOff Enable the power to be turned off with the power button Disable the power to be turned off with the power buttonHeader Bool ApoCountReset Void SoftReset Disables automatic power-on with the alarm Internal errorLanguage Interface Calling Sequence Parameters Bool bModeBool GetPowerOnAlarm Default Sample program to acquire power-on event notification Bool GetPowerEventStat SIPANEL.DLL SIPanel Library OverviewSIPANEL.EXE Use of SIPanel Library RestrictionsProgram for starting up the library RegistryLpctstr lpParam Sipshow SiphideSample program to start up the SIPanel Hinstance LptstrSample program of application software for business use Tchar ClassName = Text CallSipTchar ClassNameTSR = TEXTSipTsr HbCallText = CreateWindow TEXTbutton, TEXTText AreaWsvisible Wsoverlapped Wssysmenu HWnd = CreateWindowClassName, ClassNameLpCmdLine Find SipTsr Px,y Options of Command LineSw,h O Bootup Library Overview FunctionIOBOX1.DLL PortInfinite = No timeout Dword294,967,295 msec. equals to Infinite Fail to call the functionMultiple-Thread Mode Sequential ModeUse of ioboxchk Hwnd Sample Program= Null Wsoverlapped WINDOWWIDTH/2WINDOWHEIGHT/2 NullCase Wmpaint Wait for 5 seconds Enable the power on event notification Disable the power on by alarmRegistry of Libraries RS-232C Interface File Transfer Utility OverviewIrDA 1.0 Interface List of Supported Commands Use of Flce Termination of FlceOperation Input ParameterRestrictions Communication Commands OptionsTypes of Arguments OverwriteMethod of Describing Pathname Reference Storage Card PC card My Documents Internal RAMWindows95 /Windows NT Required Error if omitted Specifying Non-existing FileDOS Windows CESetting Up Registry Setting Up ItemsSetting Up Registry with User Application Hkey hKey1Long lReg1 Dword Disp1Err=FALSE Else If err==TRUE Return errTermination Codes Should take an action that is appropriate to each definitionError Code Meaning Possible Cause Remedy Log File Log File NameLocation of Log File Method of Creation12Precautions Details of Command and Option Transmission file pathname Destination directory pathnameFlce /S \casio\*.dat d\casiodat\ Flce /SR \casio\*.dat d\casiodat\Pathname Pathname of requested file\12\*.dat d\casio\*.* \casio data\ Flce /RR a\12\*.dat d\casio\*.* \casio data\Target file pathname Appended file pathnameFlce /A \MY\casio.dat b\your\master.dat Pathname of file to be deleted Without the R option Source pathname Destination pathnameFlce /N a\ 12\kk.dat a\casio\ Flce /N a\12\kk.dat a\casio\sj.datParameters None SetupExample Flce /SR \casio ap\*.* \casio ap\ /TSession with PC Flce casio.scrFlce /Y=COM1, , casio.scr Session between PA-2400W-and-PA-2400WCommand and Status Idle notificationRetry Process When Downloading File Retry MethodPreparation at PC \soft\Preparation at PA-2400W RestrictionRetry.scr List of Commands File Check Utility OverviewDownloading file from PC to PA-2400W Operation MethodOperation Transmission side PA-2400W Copying file with PC card from PA-2400W to PA-2400WCopy PC card Describing Method 1Pathname Details about Command and Option Examples of specification for command and optionExamples of Correct Startup Example of Incorrect Startup no /G or /C optionCommand of Fchkce 1Generation of List File Comparison by List File \AP\MENU.EXE 12345 \CONFIG.SYS 1000 \AUTOEXEC.BAT 512 Format of List FileExample FILENO=3Syntax Analysis of Script File Childproccmd = COption = Recursiveoption Updateoption Recursiveoption = R Error Messages/Codes Restriction Option /SCSpecification of a script file name Specification of recursive callAO Append output File name list or Script file nameDestination directory name FCHK.LOG file output directory name\casio\ .dat \casio data\ \casio\ Fchkce /G /R \casio\ .dat \casio data\ \casio\Does not compare the update data OptionFCHK.LOG file pathname Fchkce /C \casio data\