Casio manual Restriction, Preparation at PA-2400W, Retry.scr

Page 68

Preparation at PA-2400W

The flow of retry operation is as follows. The operation is recommended only if such error as 0x0100 protocol error (data error on line) or 0xA020 line broken error occurs.

Retry counter +=1

FLCE “normal transmission.scr”

Return value = 0x0100 or 0xA020 ?

Fig. 6.xx

Yes

 

 

No

 

 

 

 

 

 

 

 

 

 

FLCE

“retry.scr”

 

 

 

 

 

Return value = 0x0100 or 0xA020 ? Yes and retry counter < limited value ? Yes

Fig. 7.1

According to the flow chart above, another retry after the initial retry operation can be possible. However, if there is fatal error exists, recovery routine of the error may run into a trap and never be able to escape from it. One time retry operation can recover from most of error states.

7.15.3 Restriction

When you download a file to the PA-2400W where the same file exists, set up newer date time/date into the file before downloading it. This will avoid unnecessary retry operation which is started up by the time/date verification function.

68

Image 68
Contents PA-2400W Library Manual VersionTable of Contents Fchkce /G Fchkce /C Preface CasioBootup Library Supported FilesSystem Library SIPanel LibrarySystem configuration Host PC PA-2400W CopySIPanel Library 3 I/O Bootup LibraryDedicated Library and Utility System Library File Transfer Utility File Check UtilityDevelopment Environment System Library Overview Details of Function Title FunctionParameters None Return Values Header #include CasioSys.h RemarksTurns off the backlight Language Interface Calling Sequence True Backlight is onFalse Backlight is offHeader #include CasioSys. h Remarks DisablePowerOff Bool EnablePowerOff Header Disable the power to be turned off with the power buttonEnable the power to be turned off with the power button Bool ApoCountReset Void SoftReset Disables automatic power-on with the alarm Internal errorLanguage Interface Calling Sequence Parameters Bool bModeBool GetPowerOnAlarm Default Sample program to acquire power-on event notification Bool GetPowerEventStat SIPANEL.EXE SIPanel Library OverviewSIPANEL.DLL Use of SIPanel Library RestrictionsProgram for starting up the library RegistryLpctstr lpParam Sipshow SiphideSample program to start up the SIPanel Hinstance LptstrSample program of application software for business use Tchar ClassName = Text CallSipTchar ClassNameTSR = TEXTSipTsr HbCallText = CreateWindow TEXTbutton, TEXTText AreaLpCmdLine HWnd = CreateWindowClassName, ClassNameWsvisible Wsoverlapped Wssysmenu Find SipTsr Sw,h Options of Command LinePx,y O Bootup Library Overview FunctionIOBOX1.DLL PortInfinite = No timeout Dword294,967,295 msec. equals to Infinite Fail to call the functionUse of ioboxchk Sequential ModeMultiple-Thread Mode = Null Sample ProgramHwnd Wsoverlapped WINDOWWIDTH/2WINDOWHEIGHT/2 NullCase Wmpaint Wait for 5 seconds Registry of Libraries Disable the power on by alarmEnable the power on event notification IrDA 1.0 Interface File Transfer Utility OverviewRS-232C Interface List of Supported Commands Use of Flce Termination of FlceOperation Input ParameterRestrictions Communication Commands OptionsTypes of Arguments OverwriteMethod of Describing Pathname Reference Storage Card PC card My Documents Internal RAMWindows95 /Windows NT Required Error if omitted Specifying Non-existing FileDOS Windows CESetting Up Registry Setting Up ItemsSetting Up Registry with User Application Hkey hKey1Long lReg1 Dword Disp1Err=FALSE Else If err==TRUE Return errTermination Codes Should take an action that is appropriate to each definitionError Code Meaning Possible Cause Remedy Log File Log File NameLocation of Log File Method of Creation12Precautions Details of Command and Option Transmission file pathname Destination directory pathnameFlce /S \casio\*.dat d\casiodat\ Flce /SR \casio\*.dat d\casiodat\Pathname Pathname of requested file\12\*.dat d\casio\*.* \casio data\ Flce /RR a\12\*.dat d\casio\*.* \casio data\Flce /A \MY\casio.dat b\your\master.dat Appended file pathnameTarget file pathname Pathname of file to be deleted Without the R option Source pathname Destination pathnameFlce /N a\ 12\kk.dat a\casio\ Flce /N a\12\kk.dat a\casio\sj.datParameters None SetupExample Flce /SR \casio ap\*.* \casio ap\ /TSession with PC Flce casio.scrFlce /Y=COM1, , casio.scr Session between PA-2400W-and-PA-2400WCommand and Status Idle notificationRetry Process When Downloading File Retry MethodPreparation at PC \soft\Retry.scr RestrictionPreparation at PA-2400W List of Commands File Check Utility OverviewOperation Operation MethodDownloading file from PC to PA-2400W Copy PC card Copying file with PC card from PA-2400W to PA-2400WTransmission side PA-2400W Describing Method 1Pathname Details about Command and Option Examples of specification for command and optionExamples of Correct Startup Example of Incorrect Startup no /G or /C optionCommand of Fchkce 1Generation of List File Comparison by List File \AP\MENU.EXE 12345 \CONFIG.SYS 1000 \AUTOEXEC.BAT 512 Format of List FileExample FILENO=3Syntax Analysis of Script File Childproccmd = COption = Recursiveoption Updateoption Recursiveoption = R Error Messages/Codes Restriction Option /SCSpecification of a script file name Specification of recursive callAO Append output File name list or Script file nameDestination directory name FCHK.LOG file output directory name\casio\ .dat \casio data\ \casio\ Fchkce /G /R \casio\ .dat \casio data\ \casio\Does not compare the update data OptionFCHK.LOG file pathname Fchkce /C \casio data\