Mechanical and Environmental

Dimensions

Length:

7.28” (18.5cm)

 

Width:

3.49” (8.76cm)

 

Depth:

1.70” (4.33cm)

Weight

15.59 oz. (442g) with battery pack

IP Rating

IP 65

 

Temperature

Operation: -5°C to 50°C

 

Storage: -20°C to 60°C

Humidity

5% to 95% RH non-condensing

Shock

Multiple 4.0’ (1.2m) drops to concrete

Docking Station

Interface

1 EIA RS232C IDC type connector via PC/computer, 1 USB port

Power Input

16 pin connector for charging and communication pads to main

 

unit

 

Quick charging typically takes 3 hours

 

AC/DC adapter @ 12 VDC/2A with regulator

 

 

Pin Assignment of Charge

 

 

and Communication Port

 

 

 

 

P in

A ssig nm ent

Description

 

1

D CD

 

 

 

 

 

 

2

RX D

Receive Data

 

3

T XD

S e nd Data

 

 

 

 

 

4

DTR

Data T ransm it Re ady

 

5

S G

S ig nal Gro und

 

 

 

 

 

6

DS R

Data S et Re ady

 

 

 

 

 

7

RT S

Re quest to Se nd

 

 

 

 

 

8

CT S

Clear to Send

 

 

 

 

 

9

RI

Ring Indicator

 

 

 

 

 

10

US B 5V

US B 5V

 

 

 

 

 

11

12V

12V Input

 

12

NC

 

 

 

 

 

 

13

NC

 

 

14

G DN

G round

 

 

 

 

 

15

UDC

U SB Differential Data Signal High Side

 

 

 

 

 

16

/UDC

U S B Differential D ata Sig nal Low S ide

 

 

 

 

 

Product Reference Guide

47

Image 47
Contents Unitech PA962 Introduction ChapterChapter Useful Application Program Chapter CommunicationIntroduction Product Reference Guide Pulling-tags RF Card Cushion Unitech PA962 & AccessoriesPA962 Back View Tour of the Unitech PA962First Steps with the Unitech PA962 Installing the Battery PackCharging the Main and Backup Batteries for the First Time Supplying Power to the PA962Insert CF card to PA962 Using the StylusPcmcia Pulling Tags First Operation of the Unitech PA962 Exiting Date/Time Properties Settings Flash Memory Alpha KeypadCursor Key Alpha KeyUseful hotkeys Software Keyboard Windows CE Keyboard Laser Scanner Using the Laser ScannerPower system Charging the Lithium-Ion Battery PackCharging the Main and Backup Battery for the First Time Power Status Indication Check Battery Status Checking Main and Backup Battery StatusEnter Power Properties Automatic shut-down of the PA962 How to Save Battery PowerBacklight Setting Cold Boot Warm Boot / Cold BootAutomatically turn on the backlight when key Warm BootCharging Considerations Storage and Safety PrecautionsDocking Station ConnectingIntroduction Serial or USB CableActiveSync Installing Microsoft ActiveSyncInstallation Unitech PA962 Page Unitech PA962 Using the Mobile Devices Window Changing Communications Settings Synchronization Files What Gets SynchronizedChanging Synchronization Options Installing and Removing SoftwareSending Mail Remotely InBoxSending and Receiving E-Mail with InBox Work Remotely Setting Up Remote MailReceiving Messages Sending Messages RF CommunicationSetting Up the Wireless Card Installing the Wireless Local Area Network Wlan CardGateway Obtaining an IP Address via Dhcp ServerSpecifying an IP Address IP AddressOpen My Computer or use File Explorer Cisco 350 Site Survey ToolLucent WaveLAN Agere Orinoco = Tap Start, Control Panel Power ManagementScan2Key Scanner SettingSet customization symbologies for each symbology including Barcode Symbologies Input/Output CPU/MemoryIrDA Laser Typical Depth of FieldInterface Port Ing PortOS and Software Programming Tools PowerBarcode/Symbology Communication Port Mechanical and EnvironmentalDocking Station Appendix B Update and Upgrade OS Page Appendix C Laser Information