IP | KSU Installation |
|
|
2.2.7 External backup batteries installation
In case of power failure, the external backup batteries automatically maintain uninterrupted power for the IP
Figure 2.2.7 External Back Up Battery Installation
※Note : The cable for connecting the battery is supplied with the KSU.
Operation of the batteries is controlled by the MBUB. This IP
The external batteries can maintain system operation as needed depending on several elements such as, battery charge status, condition and capacity of the batteries, and system configuration (number of station ports).
CAUTION
•It is recommended to use a fuse (5A @250V) between battery and system.
•Recommended battery capacity is 24V/10AH MF battery; the IP
•Carefully check the battery polarity with cable colors (RED and BLUE) when connecting the battery to the system.
•Make sure that you do not
•There is a danger of explosion if external backup batteries are incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
16