Panasonic KX-TC1205RUF, KX-TC1205RUW manual Adjustments Base Unit, Test Mode Flow Chart Base Unit

Page 23

KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF

8 ADJUSTMENTS (BASE UNIT)

If your unit have below symptoms, adjust or confirm each item using remedy column from the table.

Symptom

Remedy*

The base unit dose not respond to a call from handset.

Make adjustments in item (A)

The base unit dose not transmit or the transmit frequency is off.

Make adjustments in item (B)

The transmit frequency is off.

Make confirmation in item (C)

The transmit power outlet is low, and the operating distance between the base unit and the

Make confirmation in item (D)

handset is less than normal.

 

The reception sensitivity of base unit is low with noise.

Make confirmation in item (E)

The transmit level is high or low.

Make confirmation in item (F)

The reception level is high or low.

Make adjustments in item (G)

The unit does not link.

Make confirmation in item (H)

*: Refer to Adjustment (P.24).

8.1.Test Mode Flow Chart (Base Unit)

The operation-flow of Test mode and main check items are shown below.

Note:

**: Refer to the above table.

23

Image 23
Contents KX-TC1205RUB KX-TC1205RUW KX-TC1205RUS KX-TC1205RUF Contents Accessories and Packing Materials Recharge Battery information BatteryBattery Replacement Base Unit Handset Location of ControlsConnection KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF Adding Another Phone Making Calls Answering Calls OperationsKX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF Flash Button Show in Fig To remove Remove Disassembly InstructionsRear Cabinet Battery compartment cover Troubleshooting Guide Check Power Bell Reception Check Battery Charge CPU IC2 RF IC IC1 Check LinkRefer to Adjustment P.27 Check Handset Reception Check Handset TransmissionTest Mode Flow Chart Base Unit Adjustments Base UnitAdjustment How to change the channelIC3 Adjustment Standard Base UnitTest Mode Flow Chart Handset Adjustments HandsetIC1 How to change the channel AdjustmentComponent View Adjustment Standard HandsetFlow Solder Side View Base Unit RF SpecificationHOW to Check the Handset Speaker Frequency Table MHz STAND-BY TALK, Talk STAND-BY Explanation of CPU Data CommunicationRinging Changing the Channel Ports for transmitting and receiving of data IC1 Block Diagram Base UnitIC1 Block Diagram HandsetOutline Circuit OperationPower Supply Circuit Reset Circuit Base Unit Telephone Line Interface Charge CircuitBase to Handset Transmitter/ReceiverHandset to Base Signal Route Circuit Operation Handset Reset Circuit HandsetBattery Low / Power Down Detector 18.1. IC2 19.1. IC2 Preparation HOW to Replace Flat Package ICProcedure Modification Procedure of BridgeCabinet and Electrical Parts Location Base Unit Cabinet and Electrical Parts Location Handet Accessories and Packing Materials Cabinet and Electrical Parts Replacement Parts ListDiodesi ZNR1 ERJ3GEYJ514 PQXA36ASVC Battery ERJ3GEYJ202 Accessories and Packing Materials Handset Schematic Diagram Handset For Schematic DiagramBase Unit Schematic Diagram Base Unit 26.1 Base Unit Schematic Diagram Base UnitFILTER\2 26.2 RF Unit Base Unit27.1 Handset Schematic Diagram Handset450kHz RF Unit HandsetKX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF Circuit Board Base Unit IC1 IC4 IC2 IC3 Circuit Board Handset RX VCO TX VCO KXTC1205RUB