Panasonic KX-TC1205RUB, KX-TC1205RUW, KX-TC1205RUS manual Charge Circuit, Telephone Line Interface

Page 41

KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF

16.4. Charge Circuit

Circuit Operation:

When charging the handset on the base unit, the charge current is as follows;

DC (JK2) L8 D6 L7 CHG+(Base) [CHG+(Handset) L4 Q9 BATT(1)....Battery....BATT(2) L5

CHG-(Handset)] CHG+(Base) L5,

In this way, the CPU on both unit detects the fact that the battery is charged.

The charge current is controlled by switching Q701 of Handset. The battery is charged in normal mode for 10 hours and then in trickle mode.

16.5. Telephone Line Interface

Function:

Bell signal detection

ON/OFF hook and pulse dial circuit

Side tone circuit

Bell signal detection and OFF HOOK circuit:

In the idle mode, Q103 is open to cut the DC loop current and decrease the ring load. When ring voltage appears at the Tip (T) and Ring (R) leads (when the telephone rings), the AC ring volltage is transferred as follows.

JK1 (3): T L6 R144 IC3D (12,13 14) C97 R148 Q20 IC2 (24) [BELL]

JK1 (2): R L4 R120 R152 →−

When the CPU (DSP) detects a ring signal and press the TALK Key on the handset. Q6 turns on and then RY1 turns on, thus providing an off-hook condition (active DC current flow through the circuit) and the following singal flow is for the loop current. T R160 L4 RY1 R107 T7 R116 D5 L6 R161 R [OFF HOOK]

ON HOOK Circuit:

Q6 is open, RY1 disconnected as to cut the DC loop current and to cut the voice signal. The unit is consequently in an on-hook condition.

Pulse Dial Circuit:

DSP (Relay) turns RY1 ON/OFF to make the pulse dialing via Q6.

Make/Break ratio when dialing with the Handset: 40%:60%

Side Tone Circuit:

Basically this circuit prevents the TX signal from feeding back to RX signal.

As for this unit, TX signal feed back from Q11 is canceled by the cancellor circuit of AGC.

41

Image 41
Contents KX-TC1205RUB KX-TC1205RUW KX-TC1205RUS KX-TC1205RUF Contents Accessories and Packing Materials Recharge Battery information BatteryBattery Replacement Base Unit Handset Location of ControlsConnection KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF Adding Another Phone Making Calls Answering Calls OperationsKX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF Flash Button Show in Fig To remove Remove Disassembly InstructionsRear Cabinet Battery compartment cover Troubleshooting Guide Check Power Bell Reception Check Battery Charge CPU IC2 RF IC IC1 Check LinkRefer to Adjustment P.27 Check Handset Reception Check Handset TransmissionTest Mode Flow Chart Base Unit Adjustments Base UnitAdjustment How to change the channelIC3 Adjustment Standard Base UnitTest Mode Flow Chart Handset Adjustments HandsetIC1 How to change the channel AdjustmentComponent View Adjustment Standard HandsetFlow Solder Side View Base Unit RF SpecificationHOW to Check the Handset Speaker Frequency Table MHz STAND-BY TALK, Talk STAND-BY Explanation of CPU Data CommunicationRinging Changing the Channel Ports for transmitting and receiving of data IC1 Block Diagram Base UnitIC1 Block Diagram Handset Outline Circuit OperationPower Supply Circuit Reset Circuit Base Unit Telephone Line Interface Charge CircuitBase to Handset Transmitter/ReceiverHandset to Base Signal Route Circuit Operation Handset Reset Circuit HandsetBattery Low / Power Down Detector 18.1. IC2 19.1. IC2 Procedure HOW to Replace Flat Package ICModification Procedure of Bridge PreparationCabinet and Electrical Parts Location Base Unit Cabinet and Electrical Parts Location Handet Accessories and Packing Materials Cabinet and Electrical Parts Replacement Parts ListDiodesi ZNR1 ERJ3GEYJ514 PQXA36ASVC Battery ERJ3GEYJ202 Accessories and Packing Materials Handset Schematic Diagram Handset For Schematic DiagramBase Unit Schematic Diagram Base Unit 26.1 Base Unit Schematic Diagram Base UnitFILTER\2 26.2 RF Unit Base Unit27.1 Handset Schematic Diagram Handset450kHz RF Unit HandsetKX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF Circuit Board Base Unit IC1 IC4 IC2 IC3 Circuit Board Handset RX VCO TX VCO KXTC1205RUB