Panasonic KX-TC1205RUF, KX-TC1205RUW, KX-TC1205RUB manual How to change the channel Adjustment, IC1

Page 27

KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF

9.2.How to change the channel

9.3.Adjustment

 

Adjustment Items

Test Mode

Adjustment

Procedure

Check or

 

 

 

Point

 

Replace

 

 

 

 

 

Parts

(A)

Battery Low

3ch Talk

-

1. Set the power supply voltage to DC3.60V, and confirm so that the reading

IC1

 

Confirmation

 

 

of oscillosope is High.

 

 

 

 

 

2. Set the power supply voltage to DC 3.40V, and confirm so that the

 

 

 

 

 

reading of oscilloscope is Low.

 

(B)

TX VCO

3ch Talk

T6

1. Adjust T6 so that the reading of the Digital Voltmeter is 1.0V ± 0.1V.

IC1, X1,

 

Voltage

 

 

 

T6

(C)

RX VCO

3ch Talk

-

Confirm RX VCO voltage so that the reading of the Digital Voltmeter is

IC1, X1,

 

Confirmation

 

 

2.9V ± 0.5V.

T6

 

 

 

 

 

L6, C24

(D)

TX Frequency

3ch Talk

VC1

Adjust VC1 so that the reading of the frequency counter is 39.875MHz ±

IC1, VC1

 

Adjustment

 

 

0.1KHz.

DPX1, T5

(E)

TX Power

3ch Talk

T5

Adjust T5 so that the reading of the RF VTVM (50Ω load) is 5dBm ±

DPX1, Q5,

 

Adjustment

 

 

1dBm.

T5

(F)

RX Sensitivity

3ch Talk

T3

1. Apply -60dBm output from S.S.G. (modulation frequency 1KHz, dev.

DPX1,

 

Adjustment

 

 

0KHz).

T3,IC1,

 

(2nd IF output)

 

 

2. Adjust T3 so that the reading of RF VTVM is more than 15mV.

CF1, CF2

 

 

 

 

 

(G)

Noise Squelch

3ch Talk

-

1. Measure the SSG output level when the noise squelch changes from Low

IC1, DPX1

 

Confirmation

 

 

to High. (modulation frequency 1KHz, dev.3kHz)

 

 

 

 

 

2. Confirm so that the SSG output level is -105dBm.

 

(H)

Speaker

3ch Talk

-

1. Apply -60dBm output from S.S.G. (modulation frequency 1KHz, dev.

IC1

 

Output Level

 

 

3KHz).

 

 

confirmation

 

 

2. Confirm so that SP output level is 120mV ± 30mV.

 

 

 

 

 

 

 

 

 

 

(distortion: less than 7%) (volume High).

 

(I)

Mic Modulation

3ch Talk

-

1. Apply a MIC signal (1KHz, 2.4mV at 600Ω load).

IC1, DV1

 

Factor

 

 

2. Confirm so that the reading FM Deviation Meter is 3.1KHz ± 0.4KHz.

 

 

Confirmation

 

 

 

 

 

 

 

 

(J)

Data

3ch Talk

-

Confirm so that the reading of the FM Deviation Meter is 5kHz ± 1kHz.

 

 

Modulation

 

 

 

 

 

Confirmation

 

 

 

 

The connections of adjustment equipment are as shown in Adjustment Standard (Handset) (P.28).

SSG Frequency: 30.175 MHz

27

Image 27
Contents KX-TC1205RUB KX-TC1205RUW KX-TC1205RUS KX-TC1205RUF Contents Accessories and Packing Materials Recharge Battery information BatteryBattery Replacement Base Unit Handset Location of ControlsConnection KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF Adding Another Phone Making Calls Answering Calls OperationsKX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF Flash Button Show in Fig To remove Remove Disassembly InstructionsRear Cabinet Battery compartment cover Troubleshooting Guide Check Power Bell Reception Check Battery Charge CPU IC2 RF IC IC1 Check LinkRefer to Adjustment P.27 Check Handset Reception Check Handset TransmissionTest Mode Flow Chart Base Unit Adjustments Base UnitAdjustment How to change the channelIC3 Adjustment Standard Base UnitTest Mode Flow Chart Handset Adjustments HandsetIC1 How to change the channel AdjustmentComponent View Adjustment Standard HandsetFlow Solder Side View RF Specification HOW to Check the Handset SpeakerBase Unit Frequency Table MHz STAND-BY TALK, Talk STAND-BY Explanation of CPU Data CommunicationRinging Changing the Channel Ports for transmitting and receiving of data IC1 Block Diagram Base UnitIC1 Block Diagram HandsetOutline Circuit OperationPower Supply Circuit Reset Circuit Base Unit Telephone Line Interface Charge CircuitBase to Handset Transmitter/ReceiverHandset to Base Signal Route Circuit Operation Handset Reset Circuit HandsetBattery Low / Power Down Detector 18.1. IC2 19.1. IC2 Preparation HOW to Replace Flat Package ICProcedure Modification Procedure of BridgeCabinet and Electrical Parts Location Base Unit Cabinet and Electrical Parts Location Handet Accessories and Packing Materials Cabinet and Electrical Parts Replacement Parts ListDiodesi ZNR1 ERJ3GEYJ514 PQXA36ASVC Battery ERJ3GEYJ202 Accessories and Packing Materials For Schematic Diagram Base Unit Schematic Diagram Base UnitHandset Schematic Diagram Handset 26.1 Base Unit Schematic Diagram Base UnitFILTER\2 26.2 RF Unit Base Unit27.1 Handset Schematic Diagram Handset450kHz RF Unit HandsetKX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF Circuit Board Base Unit IC1 IC4 IC2 IC3 Circuit Board Handset RX VCO TX VCO KXTC1205RUB