Panasonic KX-TDA100 Notification to the Telephone Company, Ringer Equivalence Number REN

Page 12

F.C.C. REQUIREMENTS AND RELEVANT INFORMATION

1.Notification to the Telephone Company

This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the side of this equipment is a label that contains, among other information, a product identifier in the format US: ACJMF03AKX-TDA100. If requested, this number must be provided to the telephone company.

Installation must be performed by a qualified professional installer. If required, provide the telephone company with the following technical information:

Telephone numbers to which the system will be connected

Make: Panasonic

Model: KX-TDA100 and KX-TDA200

Certification No.: found on the side of the unit

Ringer Equivalence No.: 0.3A

Facility Interface Code: 02LS2, 04DU9.BN/DN/1KN/1SN, METALLIC

Service Order Code: 9.0F, 6.0P

Required Network Interface Jack: RJ21X, RJ48C, RJ2HX

2.Ringer Equivalence Number (REN)

The REN is used to determine the number of devices that may be connected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total RENs, contact the local telephone company. The REN for this product is part of the product identifier that has the format US: ACJMF03AKX-TDA100. The digits represented by 03 are the REN without a decimal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label.

3.Incidence of Harm to the Telephone Lines

If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn't practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.

4.Changes in Telephone Company Communications Facilities, Equipment, Operations and Procedures

The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.

5.Trouble with this equipment

If trouble is experienced with this equipment, for repair or warranty information, please see the attached warranty, which includes the Servicenter Directory. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved.

6.Connection to Party Line

Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information.

7.Combined Use with Alarm Equipment

12

Installation Manual

Image 12
Contents Installation Manual Hybrid IP-PBXMain Processing Card MPR Option CardCO Line Cards Extension CardsMemory Card Power Supply Units PSUsCell Stations CSsImportant Notice Important Safety Instructions Installation Manual Precaution Installation Manual Password Security When you ship the product Product ServiceFor Future Reference Structure of this Manual About the Other ManualsTrademarks Combined Use with Alarm Equipment Notification to the Telephone CompanyRinger Equivalence Number REN Incidence of Harm to the Telephone LinesKeep the Software UP-TO-DATE with the Latest Data For Cell Station Table of Contents Power Failure Connections 152 Information about the Other Cards 103Connection of Extensions 113 Connection of 2.4 GHz Portable Stations 120Revision History 186 Installation Manual Section System Outline Networking Features Built-in Small Call Center FeaturesComputer Telephony Integration CTI Features System HighlightsVoice Mail Features Paralleled Telephone FeaturesPortable Station PS Features Hospitality FeaturesBasic System Construction Basic ShelfConstruction of the Basic Shelf System Connection Diagram Hybrid IP-PBXDPT Optional Equipment Optional EquipmentModel No Model Name Description IP-GW4E Specifications General DescriptionDimension Weight when fullyExtension Connection Cable MountedCharacteristics Maximum Optional Service Cards Cards Installed in the Slots of the Hybrid IP-PBXSystem Capacity Card Type Maximum Number Installed MPRLCOT4 LCOT8 LCOT16 PRI23 IP-GW4 IP-GW4E IP-GW16 Cards Mounted on Other Optional Service Cards Maximum Terminal EquipmentCard Type Maximum Number Mounted on KX-TDA100 KX-TDA200 MEC Card Calculation MEC Card CalculationCalculation Example KX-TDA100 Equipment Type MEC FigurePower Supply Unit Selection Load Figure CalculationPSU Capacity Equipment Type Load FigureCalculation Example KX-TDA200 Specifications Section Installation Before Installation Before InstallationSafety Installation Instructions Installation PrecautionsBefore Installation Installation of the Hybrid IP-PBX UnpackingNames and Locations Inside ViewOpening/Closing the Front Cover Opening the Front CoverClosing the Front Cover Installing/Replacing the Power Supply Unit Accessories and User-supplied ItemsSafety Instructions User-supplied not included Grounding wireInstalling the Power Supply Unit Replacing the Power Supply Unit Replace the PSU Test Procedure Frame Ground ConnectionConnect the frame of the Hybrid IP-PBX to ground Installing/Removing the Optional Service Cards Installing Optional Service CardsBack Board Release Lever Covering the Blank Slots Handling of the Cables Removing the Optional Service Cards Types of Connectors Connector Type Pin Number Used forCTI-LINK KX-TDA0410 MPR USB When connecting an IP-GW16/IP-EXT16 card When connecting an extension cardAttaching a Ferrite Core Installation of the Hybrid IP-PBX Fastening Amphenol Connector Amphenol Connector Pin Assignment Chart LCOT8 LCOT16 DHLC8 DLC8 DLC16 MSLC16 SLC8Wall Mounting KX-TDA200 Installation of the Hybrid IP-PBX Wall Mounting KX-TDA100 WallInstallation of the Hybrid IP-PBX Floor Standing KX-TDA200 Only TOP Front Surge Protector Installation InstallationOverview IP-PBXOutside Installation Installation of a Grounding RodInstallation of the Hybrid IP-PBX Information about the Main Processing Card MPR CardUSB BGM/MOH Batt Alarm SD AccessLED Indications Indication Color DescriptionMEC Card KX-TDA0105 RMT Card KX-TDA0196 Information about the CO Line Cards LCOT8 Card KX-TDA0180 and LCOT16 Card KX- TDA0181LED Amphenol Connector Signal Name FunctionPin Assignments Card Status2 CID8 Card KX-TDA0193 Switch Settings Switch Type Usage and Status Definition SlideSwitch 3 T1 Card KX-TDA0187RJ45 Connector Signal Name Level Function4 PRI23 Card KX-TDA0290 Link RJ45 Connector 10BASE-T Signal Name Input I/Output O FunctionIP-GW4 Card KX-TDA0480 Alarm OnlineIAM Busy DataRJ45 Connector 10BASE-T/100BASE-TX IP-GW4E Card KX-TDA0484OFF IP-GW16 Card KX-TDA0490 LED Indications Information about the Extension Cards CSIF4 Card KX-TDA0143 and CSIF8 Card KX-TDA0144Editing the CS Name using the KX-TDA Maintenance Console Example When the CSIF4 card has been installed*1Powh PowlLED Indications DHLC8 Card KX-TDA0170 D2A D1AD2B D1BLED Indications 3 DLC8 Card KX-TDA0171 Data port 1 Low 4 DLC16 Card KX-TDA0172 D2I D1ID2J D1J5 SLC8 Card KX-TDA0173 Pin Assignments EXT-CID Card KX-TDA0168 7 SLC16 Card KX-TDA0174 and MSLC16 Card KX- TDA0175 Ring port Tip port 17-25 Reserved 42-50 IP-EXT16 Card KX-TDA0470 Online Accessories included none User-supplied not included none Information about the Other Cards1 OPB3 Card KX-TDA0190 User-supplied not included Copper wire 2 DPH4 Card KX-TDA0161Pin Terminal Block DP4DP3 DP23 EIO4 Card KX-TDA0164 Pin Assignments Connection Diagram External SensorExternal Relay ECHO16 Card KX-TDA0166 5 MSG4 Card KX-TDA0191 CTI-LINK Card KX-TDA0410 Link Status Connection of Extensions PT-interface CS DSS ConsoleUsing a Modular T-Adaptor Parallel Connection of the ExtensionsWith APT With DPTUsing an EXtra Device Port With KX-T7600 Series DPTDptslt To Main Unit Pabx To TEL With Other DPTDigital EXtra Device Port Digital XDP Connection With KX-T7600 Series DPTBack View of DPTs To TEL First Party Call Control CTI Connection Connection of 2.4 GHz Portable Stations OverviewCS Cell Station KX-TDA0142/KX-T0141 PS 2.4 GHz Portable Station KX-TD7680/KX-TD7690Connection of 2.4 GHz Portable Stations Procedure Overview Investigate the installation sitePrepare the CS for site survey Conduct the site surveyFinish the site survey Mount the CS on the wallCharacteristics of Radio Waves Site PlanningUnderstanding Radio Waves Object Material Transmission Tendency Radio Signal Strength Levels CS Coverage AreaSite Survey Preparation Example Installing in a Room Separated by Interior Walls CS installation planThings to take note Setting and Installing the CS Temporarily for Site Survey DIP SwitchBefore Site Survey Connection of 2.4 GHz Portable Stations Testing the Radio Signal Strength Site SurveyPS CS NO.1 LEVEL12 Referring to the Stored Scan Data Deleting the Stored Scan Data After Site Survey Connecting a Cell Station to the Hybrid IP-PBX Using a Csif CardAccessories and User-supplied Items for the CS Powh PowlUsing a DHLC/DLC Card Connecting the CS Entering the System Programming Mode Registering the PSWhen the PS has not been registered yet PS RegistrationSetting the System Lock Setting the PIN for Hybrid IP-PBX Setting the PIN for PS Using the KX-TD7680692 Testing the Operation PS TerminationWall Mounting 71 mm 13/16 Install a screw here Reference for Wall MountingInstalling the Doorphone KX-T30865 Maximum Cabling DistanceConnection Installation Manual Connection of Peripherals Connection of PeripheralsBGM Connection Charts PagerPC/Printer via RS-232C Pin AssignmentsFor connecting a printer/PC with a 25-pin RS-232C connector RS-232C SignalsSignal Ground SG Receive Data RXD…inputPC/CTI Server via USB version VbusUSB D USB D+Power Failure Connections Power Failure ConnectionsRJ11 Connector Pin Assignments for CO line Card RJ11 Connector Pin Assignments for Extension CardPFT Ports 1 Signal Name Function PFT Ports 3 and 4 for LCOT16 card only Signal Name FunctionStarting the Hybrid IP-PBX Starting the Hybrid IP-PBXRUN Confirming the CO Line Connection Section Guide for the KX-TDA Maintenance Console KX-TDA Maintenance Console*1 OverviewConnection ConnectionSerial Interface Connection LAN Connection via CTI-LINK CardExternal Modem Connection RD RXD SD TXD ER DTR DR DSRInstallation of the KX-TDA Maintenance Console Installing and Starting the KX-TDA Maintenance ConsoleInstalling the KX-TDA Maintenance Console System RequirementsStart the KX-TDA Maintenance Console from the Start menu Installation of the KX-TDA Maintenance Console Installation of the KX-TDA Maintenance Console Section Troubleshooting Troubleshooting InstallationProblem Probable Cause Solution Cause CO line is connected to the T2/R1 Operation Problem Probable Cause Solution Using the Reset Button OperationTroubleshooting by Error Log Error Log Display FormatDescription Description List of Errors and Solutions Error Code Error MessageSLC, CSIF, LCOT, T1, PRI OPB3, IP-GWSystem Start-up and On-line Operation MPR WDTMPR RAM Probable Cause Solution ROM NG CSIF, T1, PRI, OPB3, CTILINK, IP-GW, SLC8, IP-EXT RAM NG LcotMPR-LPR LINK, IP-GW, SLC8, IP-EXT PRI, T1IP-GW IP-GW SdramIP-GW Dpram IP-GW DSPIP-PT SUB-CPU IP-PT DhcpLAN Probable Cause Solution Section Appendix New Contents Changed ContentsRevision History Pmpr Software File VersionPmpr Software File Version Pmpr Software File Version Index Numerics MOH TDA0920 Index Panasonic Puerto Rico, Inc Copyright PSQX2228VA KK0703AH4125
Related manuals
Manual 194 pages 61.97 Kb Manual 282 pages 61.74 Kb Manual 248 pages 58.62 Kb Manual 40 pages 36.33 Kb Manual 58 pages 2.3 Kb

KX-TDA100 specifications

The Panasonic KX-TDA100 is a versatile digital hybrid telephone system designed to meet the communication needs of small to medium-sized businesses. This system blends traditional telephone functions with advanced digital technology, making it an excellent choice for organizations looking to enhance their telecommunications infrastructure.

One of the key features of the KX-TDA100 is its ability to support both digital and analog telephony, allowing businesses to integrate existing telephone lines and devices with newer technologies. The system can accommodate up to 100 extensions, making it scalable and suitable for growing businesses. Additionally, it supports a variety of communication services, including voice mail, computer telephony integration, and automatic call distribution, which enhances customer service capabilities.

The KX-TDA100 utilizes advanced digital signal processing technology, ensuring clear and reliable communication. It employs features such as call forwarding, caller ID, call waiting, and conference calling, which improve productivity and streamline communication among team members. The system also allows for the integration of mobile devices through its support for SIP trunking, enabling seamless communication even when employees are on the go.

Furthermore, the KX-TDA100 includes built-in voicemail functionality, allowing businesses to manage messages efficiently. The voicemail system supports features like voicemail-to-email, which provides users with immediate access to their messages, and the option to customize greetings and auto-attendants that enhance caller experiences.

Security is another critical aspect of the KX-TDA100. The system offers various security features to protect against unauthorized access and ensure data integrity, including encryption and secure network protocols. This attention to security makes it suitable for businesses that handle sensitive information.

Overall, the Panasonic KX-TDA100 combines flexibility, scalability, and advanced technology, making it an ideal solution for businesses looking to improve their communication systems. Its user-friendly design, robust feature set, and ability to grow with the organization make it a reliable choice for enhancing productivity and ensuring effective communication within teams and with customers. Whether deploying for day-to-day operations or accommodating remote work, the KX-TDA100 offers the reliability and features that modern businesses require.