Panasonic KX-TDA100 installation manual 4 PRI23 Card KX-TDA0290

Page 78

2.4 Information about the CO Line Cards

2.4.4PRI23 Card (KX-TDA0290)

Function

1-port ISDN Primary Rate Interface card (23B channels). NI (North American standard ISDN protocol) compliant.

LEDs

RJ45

NT1

A B

Accessories and User-supplied Items

Accessories (included): none

User-supplied (not included): RJ45 connector

Notes

Connect this optional service card to the CO line through an NT1; do not connect to the U interface of the CO line directly.

To confirm the CO line connection, refer to "Confirming the CO Line Connection" in "2.12.1 Starting the Hybrid IP-PBX".

CAUTION

PRI ports are SELV ports and should only be connected to SELV services.

Switch Settings

Switch

Type

Usage and Status Definition

 

 

 

A/B

Slide

Keep the switch at default A position. Do not change the position of this

 

 

switch.

 

 

 

78

Installation Manual

Image 78
Contents Installation Manual Hybrid IP-PBXCO Line Cards Main ProcessingCard MPR Option Card Extension CardsCell Stations Memory Card Power SupplyUnits PSUs CSsImportant Notice Important Safety Instructions Installation Manual Precaution Installation Manual Password Security When you ship the product Product ServiceFor Future Reference Structure of this Manual About the Other ManualsTrademarks Ringer Equivalence Number REN Combined Use with Alarm EquipmentNotification to the Telephone Company Incidence of Harm to the Telephone LinesKeep the Software UP-TO-DATE with the Latest Data For Cell Station Table of Contents Connection of Extensions 113 Power Failure Connections 152Information about the Other Cards 103 Connection of 2.4 GHz Portable Stations 120Revision History 186 Installation Manual Section System Outline Computer Telephony Integration CTI Features Networking FeaturesBuilt-in Small Call Center Features System HighlightsPortable Station PS Features Voice Mail FeaturesParalleled Telephone Features Hospitality FeaturesBasic System Construction Basic ShelfConstruction of the Basic Shelf System Connection Diagram Hybrid IP-PBXDPT Optional Equipment Optional EquipmentModel No Model Name Description IP-GW4E Specifications General DescriptionExtension Connection Cable DimensionWeight when fully MountedCharacteristics Maximum Optional Service Cards Cards Installed in the Slots of the Hybrid IP-PBXSystem Capacity Card Type Maximum Number Installed MPRLCOT4 LCOT8 LCOT16 PRI23 IP-GW4 IP-GW4E IP-GW16 Cards Mounted on Other Optional Service Cards Maximum Terminal EquipmentCard Type Maximum Number Mounted on KX-TDA100 KX-TDA200 Calculation Example KX-TDA100 MEC Card CalculationMEC Card Calculation Equipment Type MEC FigurePSU Capacity Power Supply Unit SelectionLoad Figure Calculation Equipment Type Load FigureCalculation Example KX-TDA200 Specifications Section Installation Safety Installation Instructions Before InstallationBefore Installation Installation PrecautionsBefore Installation Installation of the Hybrid IP-PBX UnpackingNames and Locations Inside ViewOpening/Closing the Front Cover Opening the Front CoverClosing the Front Cover Safety Instructions Installing/Replacing the Power Supply UnitAccessories and User-supplied Items User-supplied not included Grounding wireInstalling the Power Supply Unit Replacing the Power Supply Unit Replace the PSU Test Procedure Frame Ground ConnectionConnect the frame of the Hybrid IP-PBX to ground Installing/Removing the Optional Service Cards Installing Optional Service CardsBack Board Release Lever Covering the Blank Slots Handling of the Cables Removing the Optional Service Cards Types of Connectors Connector Type Pin Number Used forCTI-LINK KX-TDA0410 MPR USB When connecting an IP-GW16/IP-EXT16 card When connecting an extension cardAttaching a Ferrite Core Installation of the Hybrid IP-PBX Fastening Amphenol Connector Amphenol Connector Pin Assignment Chart LCOT8 LCOT16 DHLC8 DLC8 DLC16 MSLC16 SLC8Wall Mounting KX-TDA200 Installation of the Hybrid IP-PBX Wall Mounting KX-TDA100 WallInstallation of the Hybrid IP-PBX Floor Standing KX-TDA200 Only TOP Front Overview Surge Protector InstallationInstallation IP-PBXOutside Installation Installation of a Grounding RodInstallation of the Hybrid IP-PBX Information about the Main Processing Card MPR CardUSB BGM/MOH LED Indications Batt AlarmSD Access Indication Color DescriptionMEC Card KX-TDA0105 RMT Card KX-TDA0196 Information about the CO Line Cards LCOT8 Card KX-TDA0180 and LCOT16 Card KX- TDA0181LED Pin Assignments Amphenol ConnectorSignal Name Function Card Status2 CID8 Card KX-TDA0193 Switch Switch SettingsSwitch Type Usage and Status Definition Slide 3 T1 Card KX-TDA0187RJ45 Connector Signal Name Level Function4 PRI23 Card KX-TDA0290 Link RJ45 Connector 10BASE-T Signal Name Input I/Output O FunctionIP-GW4 Card KX-TDA0480 IAM Busy AlarmOnline DataRJ45 Connector 10BASE-T/100BASE-TX IP-GW4E Card KX-TDA0484OFF IP-GW16 Card KX-TDA0490 LED Indications Information about the Extension Cards CSIF4 Card KX-TDA0143 and CSIF8 Card KX-TDA0144Powh Editing the CS Name using the KX-TDA Maintenance ConsoleExample When the CSIF4 card has been installed*1 PowlLED Indications DHLC8 Card KX-TDA0170 D2B D2AD1A D1BLED Indications 3 DLC8 Card KX-TDA0171 Data port 1 Low 4 DLC16 Card KX-TDA0172 D2J D2ID1I D1J5 SLC8 Card KX-TDA0173 Pin Assignments EXT-CID Card KX-TDA0168 7 SLC16 Card KX-TDA0174 and MSLC16 Card KX- TDA0175 Ring port Tip port 17-25 Reserved 42-50 IP-EXT16 Card KX-TDA0470 Online Accessories included none User-supplied not included none Information about the Other Cards1 OPB3 Card KX-TDA0190 User-supplied not included Copper wire 2 DPH4 Card KX-TDA0161DP3 Pin Terminal BlockDP4 DP23 EIO4 Card KX-TDA0164 Pin Assignments Connection Diagram External SensorExternal Relay ECHO16 Card KX-TDA0166 5 MSG4 Card KX-TDA0191 CTI-LINK Card KX-TDA0410 Link Status Connection of Extensions PT-interface CS DSS ConsoleWith APT Using a Modular T-AdaptorParallel Connection of the Extensions With DPTDptslt To Main Unit Pabx To TEL Using an EXtra Device PortWith KX-T7600 Series DPT With Other DPTDigital EXtra Device Port Digital XDP Connection With KX-T7600 Series DPTBack View of DPTs To TEL First Party Call Control CTI Connection CS Cell Station KX-TDA0142/KX-T0141 Connection of 2.4 GHz Portable StationsOverview PS 2.4 GHz Portable Station KX-TD7680/KX-TD7690Connection of 2.4 GHz Portable Stations Prepare the CS for site survey Procedure OverviewInvestigate the installation site Conduct the site surveyFinish the site survey Mount the CS on the wallCharacteristics of Radio Waves Site PlanningUnderstanding Radio Waves Object Material Transmission Tendency Radio Signal Strength Levels CS Coverage AreaSite Survey Preparation Example Installing in a Room Separated by Interior Walls CS installation planThings to take note Setting and Installing the CS Temporarily for Site Survey DIP SwitchBefore Site Survey Connection of 2.4 GHz Portable Stations Testing the Radio Signal Strength Site SurveyPS CS NO.1 LEVEL12 Referring to the Stored Scan Data Deleting the Stored Scan Data After Site Survey Accessories and User-supplied Items for the CS Connecting a Cell Station to the Hybrid IP-PBXUsing a Csif Card Powh PowlUsing a DHLC/DLC Card Connecting the CS Entering the System Programming Mode Registering the PSWhen the PS has not been registered yet PS RegistrationSetting the System Lock Setting the PIN for Hybrid IP-PBX Setting the PIN for PS Using the KX-TD7680692 Testing the Operation PS TerminationWall Mounting 71 mm 13/16 Install a screw here Reference for Wall MountingInstalling the Doorphone KX-T30865 Maximum Cabling DistanceConnection Installation Manual Connection of Peripherals Connection of PeripheralsBGM PC/Printer via RS-232C Connection ChartsPager Pin AssignmentsSignal Ground SG For connecting a printer/PC with a 25-pin RS-232C connectorRS-232C Signals Receive Data RXD…inputUSB D PC/CTI Server via USB versionVbus USB D+Power Failure Connections Power Failure ConnectionsPFT Ports 1 Signal Name Function RJ11 Connector Pin Assignments for CO line CardRJ11 Connector Pin Assignments for Extension Card PFT Ports 3 and 4 for LCOT16 card only Signal Name FunctionStarting the Hybrid IP-PBX Starting the Hybrid IP-PBXRUN Confirming the CO Line Connection Section Guide for the KX-TDA Maintenance Console KX-TDA Maintenance Console*1 OverviewSerial Interface Connection ConnectionConnection LAN Connection via CTI-LINK CardExternal Modem Connection RD RXD SD TXD ER DTR DR DSRInstalling the KX-TDA Maintenance Console Installation of the KX-TDA Maintenance ConsoleInstalling and Starting the KX-TDA Maintenance Console System RequirementsStart the KX-TDA Maintenance Console from the Start menu Installation of the KX-TDA Maintenance Console Installation of the KX-TDA Maintenance Console Section Troubleshooting Troubleshooting InstallationProblem Probable Cause Solution Cause CO line is connected to the T2/R1 Operation Problem Probable Cause Solution Using the Reset Button OperationTroubleshooting by Error Log Error Log Display FormatDescription Description SLC, CSIF, LCOT, T1, PRI List of Errors and SolutionsError Code Error Message OPB3, IP-GWSystem Start-up and On-line Operation MPR WDTMPR RAM Probable Cause Solution LINK, IP-GW, SLC8, IP-EXT ROM NGCSIF, T1, PRI, OPB3, CTI RAM NG LcotMPR-LPR LINK, IP-GW, SLC8, IP-EXT PRI, T1IP-GW Dpram IP-GWIP-GW Sdram IP-GW DSPIP-PT SUB-CPU IP-PT DhcpLAN Probable Cause Solution Section Appendix Revision History New ContentsChanged Contents Pmpr Software File VersionPmpr Software File Version Pmpr Software File Version Index Numerics MOH TDA0920 Index Panasonic Puerto Rico, Inc Copyright PSQX2228VA KK0703AH4125
Related manuals
Manual 194 pages 61.97 Kb Manual 282 pages 61.74 Kb Manual 248 pages 58.62 Kb Manual 40 pages 36.33 Kb Manual 58 pages 2.3 Kb

KX-TDA100 specifications

The Panasonic KX-TDA100 is a versatile digital hybrid telephone system designed to meet the communication needs of small to medium-sized businesses. This system blends traditional telephone functions with advanced digital technology, making it an excellent choice for organizations looking to enhance their telecommunications infrastructure.

One of the key features of the KX-TDA100 is its ability to support both digital and analog telephony, allowing businesses to integrate existing telephone lines and devices with newer technologies. The system can accommodate up to 100 extensions, making it scalable and suitable for growing businesses. Additionally, it supports a variety of communication services, including voice mail, computer telephony integration, and automatic call distribution, which enhances customer service capabilities.

The KX-TDA100 utilizes advanced digital signal processing technology, ensuring clear and reliable communication. It employs features such as call forwarding, caller ID, call waiting, and conference calling, which improve productivity and streamline communication among team members. The system also allows for the integration of mobile devices through its support for SIP trunking, enabling seamless communication even when employees are on the go.

Furthermore, the KX-TDA100 includes built-in voicemail functionality, allowing businesses to manage messages efficiently. The voicemail system supports features like voicemail-to-email, which provides users with immediate access to their messages, and the option to customize greetings and auto-attendants that enhance caller experiences.

Security is another critical aspect of the KX-TDA100. The system offers various security features to protect against unauthorized access and ensure data integrity, including encryption and secure network protocols. This attention to security makes it suitable for businesses that handle sensitive information.

Overall, the Panasonic KX-TDA100 combines flexibility, scalability, and advanced technology, making it an ideal solution for businesses looking to improve their communication systems. Its user-friendly design, robust feature set, and ability to grow with the organization make it a reliable choice for enhancing productivity and ensuring effective communication within teams and with customers. Whether deploying for day-to-day operations or accommodating remote work, the KX-TDA100 offers the reliability and features that modern businesses require.