Panasonic KX-A272 operating instructions Serial Repeater ID programming

Page 14

Serial Repeater ID programming continued.

Ensure that the repeater is switched OFF. (both LED’s are OFF)

Power ON the repeater.

Assign the repeater to a base by following either the manual or automatic registration process.

Bring the repeater into close range of the repeater on the parent level (i.e. when assigning a repeater to chain-level 3, the repeater must be brought into close range with the repeater already set to chain-level 2.).

Press the switch the corresponding number of times to set the chain-level.

(i.e. 3 times = chain-level 3 etc.).

The red LED flashes a number of times corresponding to the chain level.

NB: Pressing the switch 4 or more times corresponds to chain-level 1.

After two minutes from power ON, the new chain-level and Radio Fixed Part Identity (R.F.P.I.) are then stored into the repeaters memory, and the repeater returns to normal operation.

Please note : This function is not available for domestic DECT appliances, only PBX.

14 Operating Instructions

Image 14
Contents Model KX-A272 Table of Contents Compatibility General SafetyOverview Accessories Included EnvironmentWall Mounting ConnectionPlacement LED StatusAutomatic Registration Manual Registration Manual Registration De-Registration Verification Tone Site Survey Mode PBX option only Serial Repeater ID programming PBX option only Serial Repeater ID programming Problem Possible Cause Solution Before Requesting HelpSpecifications Technical InformationConditions of Guarantee Index Operating Instructions 0436