Page 38

General Information

Technical data about this product

Monitor station

Power supply:

24 V DC

Current consumption:

Standby: Approx. 37 mA

 

At operation: Approx. 420 mA

Dimensions:

Approx. height 136 mm x width 136 mm x depth 32 mm

Mass (Weight):

Approx. 350 g

Operating environment:

0 °C to 40 °C, Up to 90% RH

 

(Relative Humidity) non condensing

Installation method:

Wall mount (Wall mount bracket included)

External material:

Flame retardant ABS resin (panel: acrylic resin)

Note:

LTo connect to a Door Opener, make sure the Door Opener is:

Normal open (Low active)

Less than 30 V AC (1 A), 24 V DC (1 A)

Door station

Power supply*1:

Standby: Approx. 5 V DC (2 mA)

 

At operation: Approx. 20 V DC (180 mA)

Dimensions:

Approx. height 165 mm x width 90 mm x depth 35 mm

Mass (Weight):

Approx. 330 g

Operating environment:

10 °C to 50 °C, Up to 90% RH

 

(Relative Humidity) non condensing

Installation method:

Wall mount (Wall mount bracket included)

External material:

Aluminum

*1 Supplied from the monitor station.

AC adaptor (Part number: PFAP1014)

Power supply:

100 V 240 V AC, 50 Hz / 60 Hz

Output voltage:

24 V DC

Output current:

2 A

Dimensions:

Approx. height 120 mm x width 60 mm x depth 35 mm

Mass (Weight):

Approx. 310 g

Operating environment:

0 °C to 40 °C, Below 90% RH

 

(Relative Humidity) non condensing

External material:

PC + ABS

38

Image 38
Contents Installation and Operation Guide Thank you for purchasing a Panasonic Video Intercom SystemImportant Information Important safety instructions Important InformationImportant Information Additional safety information For business users in the European UnionFor your safety For best performance Included items QuantityFor German users Compatible Panasonic PBXsFor UK and Ireland users Location of controls Front view Side view Rear viewAnswer switch Talking indicatorRinger Volume switch PBX Mode switchSpeaker Water drain hole Front view Rear view CameraMicrophone Call Button Camera angle control leverBefore installation Standard installation position of the monitor station Wiring schematic diagram Power cable/wire type and distanceInstalling the door station Non polar Screw Wire Not included Introduction and Installation Introduction and Installation Installing the monitor station Introduction and Installation Introduction and Installation Power cord To attach the AC adaptor and the DC terminal to a wall Introduction and Installation Correct Incorrect To attach the power cable Monitor station DC terminalTo attach the wires When connected to a door Door Opener Using with another machineWhen connected to a PBX Please use only a Panasonic PBXTurning PBX Mode switch ON/OFF Using the Unit Connecting to a PBX Answering a door call Available answer modesPush mode Push to talk mode Using the Unit Monitoring the outside Monitor Bright TalkOpening a door Door Opener DoorTroubleshooting Problem Cause and solutionCleaning Technical data about this product General Information Copyright For your future referenceAttach your sales receipt here