Panasonic EP1060 manual After Carrying Out Safety Checks, Turn the Unit On See Page, Press, button

Page 10
HOW TO USE THE MASSAGE LOUNGER — INTRODUCTION

HOW TO USE THE MASSAGE LOUNGER — INTRODUCTION

• Here you will find an overview of how to use the massage lounger. Please refer to the pages shown for further details.

1. After Carrying Out Safety Checks, Turn the Unit On (See Page 11)

z Plug the power plug into the power socket.

1

 

x Turn the lock switch to the “open” position.

 

c Turn on the power switch on the back of the unit.

 

• Please always check for the following before using the unit.

on

- Check that there is no person, pets, or obstacles around the unit.

3

off

- Check that there are no rips in the fabric.

 

 

 

lock open

 

 

2

2. Press

button.

lock switch

 

When you press 1. After Carrying Out Safety Checks, Turn the Unit On (See Page 11) button, the Programmed Operation and Leg Massage

Buttons will flash. If the cover of the controller is open, then the Manual Operation Selection Buttons will flash.

3.Select the Desired Program or the Desired Movement on the Manual Operation (See details on page 14)

Programmed Operation

Ideal for people who feel tired all over.

Ideal for people who want to operate the massage lounger simply.

z Select the required program.

x Press the Neck/Shoulder or Lower Back Buttons if you want to focus on a particular area.

c The chair will recline to the optimum angle for the massage. The massage will then begin and continue until the end of the selected program is reached, at which time the massage will automatically stop. An average program massage is 15-17 minutes.

Manual Operation

Used for selecting a particular massage movement or area to be massaged.

Ideal for people who want to adjust movement and location during the course of a massage.

Ideal for people who want just a little more on the shoulders at the end of their massage.

z Open the cover of the controller and select the massage required. x The seat will automatically recline to the optimum massage position.

c Adjust the position and intensity of the massage rollers.
v Press z Plug the power plug into the power socket. button to complete the massage.

4. Adjust the Angle of the Backrest and Legrest (See Page 13)

Adjust the angle of the backrest and legrest to the most comfortable position.

When retracting the backrest, as the massage heads must be retracted in the interests of safety there may be a slight delay before the backrest actually starts to retract. Please continue to hold down the Reclining Button until the backrest is fully retracted.

If excessive pressure is applied to the massage heads during upper body massage, in the interests of safety the massage heads may stop moving. If this occurs, raise your body slightly before restarting it. (This may happen more frequently for people with a weight of 220 lbs. or more.)

If the massage mechanism stops (or if all markings and buttons on the controller start to flash), turn off the power switch, wait for approximately 10 seconds, and then turn the power switch on again.

5.Turn the Power Off to Finish the Massage (See Page 20)

z Turn the power switch to the “off” position. x Turn the lock switch the “lock” position. c Unplug the power cord.

on

x Turn the lock switch to the “open” position. off

lock open

2

lock switch

3

1

10

Image 10
Contents EP1061/EP1060 EP1061/EP1060 Sillón de masajeInstruccionesModeloNo. de uso Español INDEX / íNDICEEnglish See pageIMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONSSAFETY PRECAUTIONS WARNING To avoid the risk of injury, follow these precautionsWARNING To avoid damaging to the chair, follow these precautions OPERATING PRECAUTIONSCARING FOR THE MASSAGER DANGER HOW TO MOVE THE CHAIRGROUNDING INSTRUCTIONS Use the casters to move the chairEP1060 PART NAMES AND FUNCTIONSEP1061 SEATAdjustmentButtons CONTROLLER EP1061theunitUsed.legtovibrationtu on/offmassageandadjust ShoulderPositionIndicatorEnsure there is Adequate Space for Reclining SETTING UP THE MASSAGE LOUNGERWHERE TO USE THE UNIT Places to Avoid5. Turn the Power Off to Finish the Massage See Page 1. After Carrying Out Safety Checks, Turn the Unit On See Page4. Adjust the Angle of the Backrest and Legrest See Page z Plug the power plug into the power socket3. Turn the Power On BEFORE USING THE UNITAFTER CHECKING THE SURROUNDING AREA, TURN ON THE POWER z Plug the power plug into the power socketSit Down Only When the Legrest is Lowered ADJUSTING THE SEATADJUSTING THE PILLOW BEFORE SITTING DOWN2. Retracting The Seat RECLINING THE SEAT1. Reclining The Seat Approx1. Press button 3. Adjusting Shoulder PositionPROGRAMMED OPERATION 2. Select the Program You Want5. Removing Vibration and Tapping from Programs 6. Adjusting Massage Intensity4. Selecting an Area for Concentrated Massage 7. Auto Stop in Programmed Operation2. Open the Cover of the Controller MANUAL OPERATIONMANUAL OPERATION FOR THE UPPER BODY 1. Press button 3. Selecting the Massage Type RequiredAdjusting the Width between Massage Heads 4. Adjusting Manual Massage SettingsAdjusting the Vertical Position of the Massage Heads Adjusting Massage IntensityLEG MASSAGE IN MANUAL OPERATION EP1061 3. Adjusting Massage Speed3. Adjusting Massage Intensity 2. Press the Leg Massage button1. Check that there is Nothing Under the Backrest or the Legrest AFTER COMPLETING THE MASSAGERETURN THE SEAT TO THE ORIGINAL POSITION 2. Return the Seat to the Upright PositionDISCONNECT THE POWER 1. Turn Off the Power 2. Unplug the Power CordSTRONG DETAILS REGARDING PROGRAMMED OPERATIONGENTLE STRONG/NECK & SHOULDER COMBINATION STRONG/LOWER BACK COMBINATIONGENTLE/NECK & SHOULDER COMBINATION GENTLE/LOWER BACK COMBINATIONTap A DETAILS REGARDING MANUAL OPERATIONShiatsu SwedishPIPES AND PLASTIC AREAS CLEANING AND MAINTENANCEPILLOW, BACK CUSHION, SEAT AND ARMREST COVERS SEAT FABRICNothing can be felt when using Tap A, Tap B TROUBLESHOOTINGProblem Cause and RemedyThe legrest cannot be raised or lowered The power cord or power plug is abnormallyIt is not possible to recline the unit Even though I press the reclining button nothing appears to happenSPECIFICATIONS EP1061 SPECIFICATIONS EP1060INSTRUCCIONES DE SEGURIDAD CONSERVE ESTAS INSTRUCCIONESPRECAUCIONES DE SEGURIDAD ADVERTENCIA Para evitar dañar el asiento, siga estas precauciones PRECAUCIONES PARA EL FUNCIONAMIENTOCUIDADO DEL SILLóN DE MASAJE PELIGRO CONEXIÓ N A TOMA DE TIERRACÓ MO MOVER EL ASIENTO PRECAUCIÓ NASIENTO PARTES DE LA UNIDAD Y SUS FUNCIONESMasaje de rodillos de 2 formas Tapa cerrada MANDO DE CONTROL EP1061MANDO DE CONTROL EP1060 Tapa abiertaGarantice espacio suficiente para abatir el asiento MONTAJE DEL SILLÓ N DE MASAJEEMPLAZAMIENTO DE LA UNIDAD PRECAUCIONES Lugares que deben evitarse5. Apague la unidad tras finalizar el masaje ver pá gina USO DEL SILLÓ N DE MASAJES - INTRODUCCIÓ N2. Pulse el botó n 4. Ajuste el á ngulo del respaldo y del reposapiernas ver pá g1. Compruebe el á rea que rodea al silló n ANTES DEL USO DE LA UNIDADTRAS COMPROBAR EL Á REA CIRCUNDANTE, ENCIENDA LA UNIDAD 2. Compruebe la unidadADVERTENCIA AJUSTE DEL ASIENTOANTES DE SENTARSE PRECAUCIONES COLOCACIÓ N DEL COJÍN1. Reclinar el asiento RECLINAR EL ASIENTO2. Levantar el respaldo 2. Seleccione el programa deseado MODO PROGRAMADO1. Pulse el botó n 3. Ajuste la posició n de los hombros6. Ajustar la intensidad del masaje 4. Seleccione una zona para el masaje localizado5. Quitar la vibració n y percusió n de los programas 7. Parada automá tica con el modo programado2. Abra la tapa del mando de control MODO MANUALMODO MANUAL EN LA PARTE SUPERIOR DEL CUERPO 3. Seleccione el tipo de masaje deseado6. Detener el modo manual 4. Ajuste las configuraciones de masaje manual5. Parada automá tica con el modo manual Ajustar la posició n vertical de los rodillos de masaje3. Ajuste de la intensidad del masaje MASAJE DE PIERNAS CON EL MODO MANUAL EP10612. Pulse el botó n de masaje de piernas 4. Parada automá tica del masaje de piernas2. Coloque el asiento en posició n vertical DESPUÉ S DE COMPLETAR EL MASAJEDEVOLVER EL ASIENTO A LA POSICIÓ N INICIAL 3. Introduzca el mando de control en el bolsilloDESCONECTAR LA UNIDAD 1. Apague la unidad 2. Desenchufe el cable de alimentació n PRECAUCIONESSUAVE DETALLES DEL MODO PROGRAMADOFUERTE Parte superior del cuerpoAmasar/Percusión B FUERTE/CUELLO Y HOMBROSFUERTE/ZONA LUMBAR RodamientosSueco/Percusión SUAVE/CUELLO Y HOMBROSSUAVE/ZONA LUMBAR SuecoDETALLES DEL MODO MANUAL TEJIDO DEL ASIENTO LIMPIEZA Y MANTENIMIENTOTUBOS Y Á REAS DE PLÁ STICO PRECAUCIONESCausa y solució n ProblemaLOCALIZACIÓ N DE AVERÍAS Ruidos del motorLa unidad no funciona en absoluto No hay respuesta al pulsar el botó n de reclinació nEl mando de control se calienta La duració n de los programas seleccionadosDATOS TÉ CNICOS EP1061 DATOS TÉ CNICOS EP1060Page No.2EN,SP(アメリカ) PanPanasonic ConsumerP90101060231 PrintedinJapan